Evidence map›Paper›PMID 36143877›Full record

ArticleMedicina (Kaunas, Lithuania)2022

CT-Navigated Spinal Instrumentations-Three-Dimensional Evaluation of Screw Placement Accuracy in Relation to a Screw Trajectory Plan.

Arthur Gubian, Lisa Kausch, Jan-Oliver Neumann, Karl Kiening, Basem Ishak, Klaus Maier-Hein, Andreas Unterberg, Moritz Scherer

Abstract read
In one paragraph

Article in Medicina (Kaunas, Lithuania), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Arthur GubianDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Lisa KauschDivision of Medical Image Computing, German Cancer Research Center (DKFZ) Heidelberg, 69120 Heidelberg, Germany.
Jan-Oliver NeumannDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Karl KieningDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Basem IshakDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.ORCID 0000-0002-6414-4295
Klaus Maier-HeinDivision of Medical Image Computing, German Cancer Research Center (DKFZ) Heidelberg, 69120 Heidelberg, Germany.
Andreas UnterbergDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Moritz SchererDepartment of Neurosurgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.ORCID 0000-0003-1203-9351

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Objectives: In the literature, spinal navigation and robot-assisted surgery improved screw placement accuracy, but the majority of studies only qualitatively report on screw positioning within the vertebra. We sought to evaluate screw placement accuracy in relation to a preoperative trajectory plan by three-dimensional quantification to elucidate technical benefits of navigation for lumbar pedicle screws. Materials and Methods: In 27 CT-navigated instrumentations for degenerative disease, a dedicated intraoperative 3D-trajectory plan was created for all screws. Final screw positions were defined on postoperative CT. Trajectory plans and final screw positions were co-registered and quantitatively compared computing minimal absolute differences (MAD) of screw head and tip points (mm) and screw axis (degree) in 3D-space, respectively. Differences were evaluated with consideration of the navigation target registration error. Clinical acceptability of screws was evaluated using the Gertzbein−Robbins (GR) classification. Results: Data included 140 screws covering levels L1-S1. While screw placement was clinically acceptable in all cases (GR grade A and B in 112 (80%) and 28 (20%) cases, respectively), implanted screws showed considerable deviation compared to the trajectory plan: Mean axis deviation was 6.3° ± 3.6°, screw head and tip points showed mean MAD of 5.2 ± 2.4 mm and 5.5 ± 2.7 mm, respectively. Deviations significantly exceeded the mean navigation registration error of 0.87 ± 0.22 mm (p < 0.001). Conclusions: Screw placement was clinically acceptable in all screws after navigated placement but nevertheless, considerable deviation in implanted screws was noted compared to the initial trajectory plan. Our data provides a 3D-quantitative benchmark for screw accuracy achievable by CT-navigation in routine spine surgery and suggests a framework for objective comparison of screw outcome after navigated or robot-assisted procedures. Factors contributing to screw deviations should be considered to assure optimal surgical results when applying navigation for spinal instrumentation.

Indexed as

Pedicle ScrewsSpinal FusionHumansLumbar VertebraeRetrospective StudiesSpineTomography, X-Ray ComputedGertzbein–Robbins classificationnavigation-guided spine surgerypedicle screw accuracyspinal instrumentationspinal navigationthree-dimensional accuracy

Identifiers

PMID36143877
PMCPMC9506171

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.