ArticleJournal of personalized medicine2022
Personalized Superficial HDR Brachytherapy-Dosimetric Verification of Dose Distribution with Lead Shielding of Critical Organs in the Head and Neck Region.
Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Beyond TG‑43: A PRISMA-based systematic review on model-based dose-calculation algorithms in brachytherapy.Journal of applied clinical medical physics · 2026Pooled it
- Cylindrical silicone applicator for superficial brachytherapy of the finger: Design and manufacturing.Journal of contemporary brachytherapy · 2025Article
- Dosimetric Impact of Air Gaps in High-Dose-Rate Contact Interventional Radiotherapy (Modern Brachytherapy) for Non-Melanoma Skin Cancer of the Ear.Journal of clinical medicine · 2025Article
- Intensity-Modulated Interventional Radiotherapy (Modern Brachytherapy) Using 3D-Printed Applicators with Multilayer Geometry and High-Density Shielding Materials for the NMSC Treatment.Journal of personalized medicine · 2025Article
- 3D-Printed Devices in Interventional Radiotherapy (Brachytherapy) Applications: A Literature Review.Journal of personalized medicine · 2025Review
- Dosimetric evaluation and Monte Carlo simulation of a new proposed surface brachytherapy mould.Journal of contemporary brachytherapy · 2024Article
- The evolving landscape of head and neck brachytherapy: A scoping review.Journal of contemporary brachytherapy · 2024Article
- Dosimetric impact of applying a model-based dose calculation algorithm for skin cancer brachytherapy (interventional radiotherapy).Journal of contemporary brachytherapy · 2023Article
- Interventional Radiotherapy (Brachytherapy) for Nasal Vestibule: Novel Strategies to Prevent Side Effects.Journal of clinical medicine · 2023Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSurface brachytherapy, usually characterized by a high dose gradient, allows the dose to be precisely deposited in the irradiated area while protecting critical organs. When the lesion is located in the nasal or ocular region, the organ of vision must be protected. The aim of this study was to verify the dose distributions near critical organs in the head and neck region during a brachytherapy procedure using lead shielding of the eye.
methodsAnthropomorphic phantom using 3D-printing technology was prepared. The doses deposited at a point in the lens of the eye and on the surface of the eyelid, directly under the lead shield were calculated and measured using EBT3 radiochromic films. Comparison of doses planned in the treatment planning system using the TG-43 formalism, TG-186 formalism, and measured were also performed.
resultsComparing the planned and calculated doses with TG186 formalism it can be assumed that the use of lead shields is a method for protecting the organ of vision from the adverse effects of ionizing radiation.
conclusionsThe decision to use a lead shield during facial surface brachytherapy procedures should be made on a patient-by-patient basis and based on model-based calculation methods recommended by TG186.