Evidence map›Paper›PMID 36143208›Full record

ArticleJournal of personalized medicine2022

IRO/Shift Test Is Comparable to the Jobe Test for Detection of Supraspinatus Lesions.

George Fieseler, René Schwesig, Julia Sendler, Jakob Cornelius, Stephan Schulze, Wolfgang Lehmann, Souhail Hermassi, Karl-Stefan Delank, Kevin Laudner

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 3 countries.

George FieselerClinic for Orthopedic and Trauma Surgery, Sports Medicine, Clinic Hannoversch Münden, 34346 Hannoversch Münden, Germany.
René SchwesigDepartment of Orthopedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, 06120 Halle, Germany.ORCID 0000-0002-1179-9933
Julia SendlerClinic for Orthopedic and Trauma Surgery, Sports Medicine, Clinic Hannoversch Münden, 34346 Hannoversch Münden, Germany.
Jakob CorneliusDepartment of Orthopedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, 06120 Halle, Germany.ORCID 0000-0002-8944-0306
Stephan SchulzeDepartment of Orthopedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, 06120 Halle, Germany.
Wolfgang LehmannClinic for Orthopedic, Trauma and Reconstructive Surgery, Georg August University Göttingen, 37075 Göttingen, Germany.
Souhail HermassiPhysical Education Department, College of Education, Qatar University, Doha 2713, Qatar.ORCID 0000-0001-9389-8937
Karl-Stefan DelankDepartment of Orthopedic and Trauma Surgery, Martin-Luther-University Halle-Wittenberg, 06120 Halle, Germany.
Kevin LaudnerDepartment of Health Sciences, University of Colorado Colorado Springs, Colorado Springs, CO 80918, USA.
Martin Luther University Halle-Wittenberg · DEMedizinische Hochschule Hannover · DEQatar University · QAUniversity of Colorado Colorado Springs · USUniversity of Göttingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To determine how the internal rotation and shift (IRO/shift) test compares to the gold standard of clinical tests (Jobe test) for diagnosing supraspinatus lesions and to confirm these clinical results with surgical findings, 100 symptomatic patients were clinically examined between October 2018 and November 2019. All 100 patients were evaluated using both the IRO/shift test and Jobe test. A total of 48 of these patients received surgical intervention. Based on these data, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for both the IRO/shift test and Jobe test were calculated. The IRO/shift test had a sensitivity of 96% (95% CI: 82-100%), specificity of 50% (95% CI: 27-73%), PPV of 73% (95% CI: 56-86%), NPV of 91% (95% CI: 59-100%), and an accuracy of 77% (95% CI: 63-88%). The Jobe test had a sensitivity of 89% (95% CI: 72-98%), specificity of 60% (95% CI: 36-81%), PPV of 76% (95% CI: 58-89%), NPV of 80% (95% CI: 52-96%), and an accuracy of 77% (95% CI: 54-81%). These results suggest that the IRO/shift test is comparable to the Jobe test, which is often viewed as the gold standard clinical examination for assessing supraspinatus lesions. This study was approved by the Ethics Commission of the Martin Luther University Halle-Wittenberg (reference number: 2018-05).

Indexed as

clinicalexaminationrotator cuffsensitivityspecial testspecificity

Identifiers

PMID36143208
PMCPMC9506539
OpenAlexW4294308180

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.