Evidence map›Paper›PMID 36143148›Full record

ArticleJournal of personalized medicine2022

Position Classification of the Endotracheal Tube with Automatic Segmentation of the Trachea and the Tube on Plain Chest Radiography Using Deep Convolutional Neural Network.

Heui Chul Jung, Changjin Kim, Jaehoon Oh, Tae Hyun Kim, Beomgyu Kim, Juncheol Lee, Jae Ho Chung, Hayoung Byun, Myeong Seong Yoon, Dong Keon Lee

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Heui Chul JungSchool of Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.
Changjin KimDepartment of Computer Science, Hanyang University, Seoul 04763, Korea.ORCID 0000-0003-3727-6249
Jaehoon OhDepartment of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.ORCID 0000-0001-8055-1467
Tae Hyun KimDepartment of Computer Science, Hanyang University, Seoul 04763, Korea.ORCID 0000-0002-7995-3984
Beomgyu KimDepartment of Computer Science, Hanyang University, Seoul 04763, Korea.
Juncheol LeeDepartment of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.
Jae Ho ChungMachine Learning Research Center for Medical Data, Hanyang University, Seoul 04763, Korea.
Hayoung ByunMachine Learning Research Center for Medical Data, Hanyang University, Seoul 04763, Korea.
Myeong Seong YoonDepartment of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.ORCID 0000-0003-1019-3347
Dong Keon LeeDepartment of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam-si 13620, Korea.

Funding

the National Research Foundation of Korea NRF-2022R1A2C1012627
6 · The paper itself

Abstract

Background: This study aimed to develop an algorithm for multilabel classification according to the distance from carina to endotracheal tube (ETT) tip (absence, shallow > 70 mm, 30 mm ≤ proper ≤ 70 mm, and deep position < 30 mm) with the application of automatic segmentation of the trachea and the ETT on chest radiographs using deep convolutional neural network (CNN). Methods: This study was a retrospective study using plain chest radiographs. We segmented the trachea and the ETT on images and labeled the classification of the ETT position. We proposed models for the classification of the ETT position using EfficientNet B0 with the application of automatic segmentation using Mask R-CNN and ResNet50. Primary outcomes were favorable performance for automatic segmentation and four-label classification through five-fold validation with segmented images and a test with non-segmented images. Results: Of 1985 images, 596 images were manually segmented and consisted of 298 absence, 97 shallow, 100 proper, and 101 deep images according to the ETT position. In five-fold validations with segmented images, Dice coefficients [mean (SD)] between segmented and predicted masks were 0.841 (0.063) for the trachea and 0.893 (0.078) for the ETT, and the accuracy for four-label classification was 0.945 (0.017). In the test for classification with 1389 non-segmented images, overall values were 0.922 for accuracy, 0.843 for precision, 0.843 for sensitivity, 0.922 for specificity, and 0.843 for F1-score. Conclusions: Automatic segmentation of the ETT and trachea images and classification of the ETT position using deep CNN with plain chest radiographs could achieve good performance and improve the physician’s performance in deciding the appropriateness of ETT depth.

Indexed as

artificial intelligencedeep learningendotracheal tubeintubationmachine learning

Identifiers

PMID36143148
PMCPMC9503144

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.