ArticleInternational journal of environmental research and public health2022
Three-Dimensional Comparison of the Maxillary Surfaces through ICP-Type Algorithm: Accuracy Evaluation of CAD/CAM Technologies in Orthognathic Surgery.
Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Patient-specific guides and osteosynthesis versus CAD/CAM occlusal splints in orthognathic surgery: a systematic review and meta-analysis of accuracy, operative time, and complications.BMC oral health · 2026Pooled it
- Splintless approach improves surgical accuracy in Le Fort I osteotomies: a systematic review and meta-analysis.Frontiers in oral health · 2026Pooled it
- Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis.Journal of personalized medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis retrospective study aims to compare the accuracy of two different CAD/CAM systems in orthognathic surgery. The novelty of this work lies in the method of evaluating the accuracy, i.e., using an Iterative Closest Point (ICP) algorithm, which matches a pair of 2D or 3D point clouds with unknown dependencies of the transition from scan
methodsThe study population was composed of ten patients who presented to the Maxillofacial Surgery Department of the University "Sapienza" of Rome for the evaluation and management of skeletal malocclusions. The patients were divided into two groups, depending on the technique used: group 1: splintless group (custom-made cutting guide and plates); group 2: splint group (using a 3D-printed splint). STL files were imported into Geomagic
resultsGroup 1 showed a 3D error of 1.22 mm ± SD 0.456, while group 2 showed a 3D error of 1.63 mm ± SD 0.303. These results have allowed us to compare the accuracy of the two CAD/CAM systems (
conclusionsThe ICP algorithm provided a reproducible method of comparison. The splintless method would seem more accurate (
Indexed as