Evidence map›Paper›PMID 36141147›Full record

ArticleEntropy (Basel, Switzerland)2022

Practical Considerations for the Application of Nonlinear Indices Characterizing the Atrial Substrate in Atrial Fibrillation.

Emanuela Finotti, Aurelio Quesada, Edward J Ciaccio, Hasan Garan, Fernando Hornero, Raúl Alcaraz, José J Rieta

Open access · goldAbstract read
In one paragraph

Article in Entropy (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 2 countries.

Emanuela FinottiBioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain.ORCID 0000-0002-6253-6260
Aurelio QuesadaArrhythmia Unit, Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain.ORCID 0000-0003-4709-1993
Edward J CiaccioDepartment of Medicine, Division of Cardiology, Columbia University Medical Center, New York, NY 10032, USA.ORCID 0000-0001-5552-6366
Hasan GaranDepartment of Medicine, Division of Cardiology, Columbia University Medical Center, New York, NY 10032, USA.ORCID 0000-0002-6742-3660
Fernando HorneroCardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain.ORCID 0000-0002-7560-2781
Raúl AlcarazResearch Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain.ORCID 0000-0002-0942-3638
José J RietaBioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain.ORCID 0000-0002-3364-6380
Columbia University Irving Medical Center · USUniversitat Politècnica de València · ESHospital Clínico Universitario de Valencia · ESHospital General Universitario De Valencia · ESUniversity of Castilla-La Mancha · ES

Funding

Generalitat Valenciana AICO/2021/286Ministry of Science and Innovation DPI2017-83952-C3Ministry of Science and Innovation PID2021-00X128525-IV0Ministry of Science and Innovation PID2021-123804OB-I00Regional Government of Castile-La Mancha SBPLY/17/180501/000411
6 · The paper itself

Abstract

Atrial fibrillation (AF) is the most common cardiac arrhythmia, and in response to increasing clinical demand, a variety of signals and indices have been utilized for its analysis, which include complex fractionated atrial electrograms (CFAEs). New methodologies have been developed to characterize the atrial substrate, along with straightforward classification models to discriminate between paroxysmal and persistent AF (ParAF vs. PerAF). Yet, most previous works have missed the mark for the assessment of CFAE signal quality, as well as for studying their stability over time and between different recording locations. As a consequence, an atrial substrate assessment may be unreliable or inaccurate. The objectives of this work are, on the one hand, to make use of a reduced set of nonlinear indices that have been applied to CFAEs recorded from ParAF and PerAF patients to assess intra-recording and intra-patient stability and, on the other hand, to generate a simple classification model to discriminate between them. The dominant frequency (DF), AF cycle length, sample entropy (SE), and determinism (DET) of the Recurrence Quantification Analysis are the analyzed indices, along with the coefficient of variation (CV) which is utilized to indicate the corresponding alterations. The analysis of the intra-recording stability revealed that discarding noisy or artifacted CFAE segments provoked a significant variation in the CV(%) in any segment length for the DET and SE, with deeper decreases for longer segments. The intra-patient stability provided large variations in the CV(%) for the DET and even larger for the SE at any segment length. To discern ParAF versus PerAF, correlation matrix filters and Random Forests were employed, respectively, to remove redundant information and to rank the variables by relevance, while coarse tree models were built, optimally combining high-ranked indices, and tested with leave-one-out cross-validation. The best classification performance combined the SE and DF, with an accuracy (Acc) of 88.3%, to discriminate ParAF versus PerAF, while the highest single Acc was provided by the DET, reaching 82.2%. This work has demonstrated that due to the high variability of CFAEs data averaging from one recording place or among different recording places, as is traditionally made, it may lead to an unfair oversimplification of the CFAE-based atrial substrate characterization. Furthermore, a careful selection of reduced sets of features input to simple classification models is helpful to accurately discern the CFAEs of ParAF versus PerAF.

Indexed as

atrial arrhythmiaatrial fibrillationcatheter ablationclassification modelscomplex fractionated atrial electrogramnonlinear indices

Identifiers

PMID36141147
PMCPMC9497841
OpenAlexW4296108883

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.