Evidence map›Paper›PMID 36140595›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Quantification of Thyroid Viscosity in Healthy Subjects Using Ultrasound Shear Wave Dispersion (Viscosity PLUS).

Dana Stoian, Luciana Moisa, Laura Taban, Ioan Sporea, Alexandru Popa, Felix Bende, Alina Popescu, Andreea Borlea

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Dana StoianDivision of Endocrinology, Department of Internal Medicine II, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.ORCID 0000-0003-3826-4362
Luciana MoisaDrD Ultrasound Center, M. Cristea Nr. 9, 300029 Timisoara, Romania.
Laura TabanDivision of Endocrinology, Department of Internal Medicine II, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.
Ioan SporeaDivision of Gastroenterology and Hepatology, Department of Internal Medicine II, Center for Advanced Research in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.
Alexandru PopaDivision of Gastroenterology and Hepatology, Department of Internal Medicine II, Center for Advanced Research in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.ORCID 0000-0002-2451-4087
Felix BendeDivision of Gastroenterology and Hepatology, Department of Internal Medicine II, Center for Advanced Research in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.ORCID 0000-0003-3820-7325
Alina PopescuDivision of Gastroenterology and Hepatology, Department of Internal Medicine II, Center for Advanced Research in Gastroenterology and Hepatology, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.
Andreea BorleaDivision of Endocrinology, Department of Internal Medicine II, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania.ORCID 0000-0001-6046-9191
Victor Babeș University of Medicine and Pharmacy Timișoara · ROCamera de Comerț Industrie și Agricultură Timișoara · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Shear-wave elastography (SWE) is widely used in thyroid evaluation, but multiple factors influence thyroid stiffness. Estimating tissue viscosity may enhance the ultrasound diagnosis of thyroid diseases, along with the ultrasound (US) and the SWE assessment. In order to be able to detect diffuse thyroid disease by viscosity measurements, it is essential to firstly define the normal values of thyroid viscosity in healthy subjects. Currently there are no published data on thyroid viscosity measurements. This first prospective study aimed to determine the normal range of thyroid viscosity values in a cohort of healthy thyroids, as well as to determine the factors that may influence them. One hundred and twenty-one consecutive subjects without thyroid pathology were evaluated in the study by means of conventional ultrasound, two-dimensional SWE (2D SWE PLUS) and viscosity plane-wave ultrasound (ViPLUS) embedded in the Supersonic MACH

Indexed as

2D SWEnormal thyroidshear wave dispersionthyroid elastographyultrasoundVi PLUSviscosity

Identifiers

PMID36140595
PMCPMC9497532
OpenAlexW4295537200

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.