Evidence map›Paper›PMID 36140565›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences.

Hyun Kyung Lee, Ji Soo Song, Weon Jang, Dominik Nickel, Mun Young Paek

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Applications of Artificial Intelligence for Pediatric Cancer Imaging.AJR. American journal of roentgenology · 2024
    Review
  3. Review
  4. Customizing native T1 mapping: The effects of compressed sensing, deep learning-based denoising, and high-resolution on measurement of native myocardial T1.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Hyun Kyung LeeDepartment of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju 54907, Korea.
Ji Soo SongDepartment of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju 54907, Korea.
Weon JangDepartment of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju 54907, Korea.
Dominik NickelMR Application Predevelopment, Siemens Healthcare, 91052 Erlangen, Germany.
Mun Young PaekSiemens Healthineers Ltd., Seoul 03737, Korea.ORCID 0000-0001-9198-775X
Jeonbuk National University Hospital · KRSiemens Healthineers (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to evaluate the image quality of compressed-sensing accelerated single-shot fast spin-echo (SSFSECS) sequences acquired within a single breath-hold in comparison with conventional SSFSE (SSFSECONV) and multishot TSE (mTSE). A total of 101 patients who underwent liver MRI at 3 T, including SSFSECONV (acquisition time (TA) = 58−62 s), mTSE (TA = 108 s), and SSFSECS (TA = 18 s), were included in this retrospective study. Two radiologists assessed the three sequences with respect to artifacts, organ sharpness, small structure visibility, overall image quality, and conspicuity of main lesions of liver and pancreas using a five-point evaluation scale system. Descriptive statistics and the Wilcoxon signed-rank test were used for statistical analysis. SSFSECS was significantly better than SSFSECONV and mTSE for artifacts, small structure visibility, overall image quality, and conspicuity of main lesions (p < 0.005). Regarding organ sharpness, mTSE and SSFSECS did not significantly differ (p = 0.554). Conspicuity of liver lesion did not significantly differ between SSFSECONV and mTSE (p = 0.404). SSFSECS showed superior image quality compared with SSFSECONV and mTSE despite a more than three-fold reduction in TA, suggesting a remarkable potential for saving time in liver imaging.

Indexed as

breath holdingdata compressionlivermagnetic resonance imaging

Identifiers

PMID36140565
PMCPMC9497881
OpenAlexW4295063183

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.