Evidence map›Paper›PMID 36140141›Full record

ArticleBiosensors2022

Ultra-Sensitive and Semi-Quantitative Vertical Flow Assay for the Rapid Detection of Interleukin-6 in Inflammatory Diseases.

Rongwei Lei, Hufsa Arain, Maryam Obaid, Nivriti Sabhnani, Chandra Mohan

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 17 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. IL-6 Mutation Attenuates Liver Injury Caused byInternational journal of molecular sciences · 2023
    Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Rongwei LeiDepartment of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
Hufsa ArainDepartment of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
Maryam ObaidDepartment of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
Nivriti SabhnaniDepartment of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
Chandra MohanDepartment of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
University of Houston · US

Funding

Monitoring Disease in LupusR01AR074096 · NIAMS · UNIVERSITY OF HOUSTON · PI CHANDRA MOHAN · 2019 to 2026
$4.5M
NIAMS NIH HHS R01 AR074096NIH HHS AR074096
6 · The paper itself

Abstract

The inflammation biomarker Interleukin 6 (IL-6) exhibits a concentration of less than 7 pg/mL in healthy serum but increases 10-100-fold when inflammation occurs. Increased serum IL-6 has been reported in chronic diseases such as rheumatoid arthritis (RA), as well as in life-threatening acute illnesses such as sepsis and cytokine release syndrome (CRS). This work seeks to meet the demand for rapid detection of serum IL-6 both for rapid monitoring of chronic diseases and for triaging patients with acute illnesses. Following the optimization of several types of gold nanoparticles, membrane pore sizes, and buffer systems, an ultra-sensitive vertical flow assay (VFA) was engineered, allowing the detection of recombinant IL-6 in spiked buffer with a limit of detection (LoD) of 10 pg/mL and a reportable range of 10-10,000 pg/mL with a 15-min assay time. The detection of IL-6 in spiked pooled healthy serum exhibited an LoD of 3.2 pg/mL and a reportable range of 10-10,000 pg/mL. The VFA's stability was demonstrated over 1-day, two-week, four-week, and six-week storage durations at room temperature. The inter-operator CV and intra-operator CV were determined to be 14.3% and 15.2%, respectively. Three reference zones, high, low, and blank, were introduced into the cartridge to facilitate on-site semi-quantitative measurements across a 6-point semi-quantitative range. Finally, the performance of the IL-6 VFA was validated using 20 RA and 20 healthy control (HC) clinical serum samples, using ELISA as the gold standard platform. The ultra-sensitive, rapid IL-6 VFA could potentially be used to triage patients for intensive care, treatment adjustments, or for monitoring disease activity in inflammatory conditions.

Indexed as

Arthritis, RheumatoidMetal NanoparticlesAcute DiseaseBiomarkersEnzyme-Linked Immunosorbent AssayGoldHumansInflammationInterleukin-6Sensitivity and SpecificityBiomarkersGoldInterleukin-6gold nanoparticle (GNP)inflammation diseasesinterleukin-6rheumatoid arthritisserologyultra-sensitivityvertical flow assay

Identifiers

PMID36140141
PMCPMC9496834
OpenAlexW4296142205

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.