Evidence map›Paper›PMID 36138700›Full record

ArticleChildren (Basel, Switzerland)2022

Clinical Accuracy of Non-Contact Forehead Infrared Thermometer Measurement in Children: An Observational Study.

Yeon-Mi Kim, Myung-Roul Jang, Ju-Ryoung Moon, Goeun Park, Ye-Jin An, Jeong-Meen Seo

Open access · goldAbstract read
In one paragraph

Article in Children (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Yeon-Mi KimDepartment of Nursing, Heart Vascular Stroke Institute, Samsung Medical Center, Seoul 06351, Korea.ORCID 0000-0002-7197-8706
Myung-Roul JangDepartment of Nursing, Heart Vascular Stroke Institute, Samsung Medical Center, Seoul 06351, Korea.ORCID 0000-0001-9616-8606
Ju-Ryoung MoonDepartment of Nursing, Cardiac Center, Heart Vascular Stroke Institute, Samsung Medical Center, Seoul 06351, Korea.ORCID 0000-0002-4285-0295
Goeun ParkBiomedical Statistics Center, Research Institute for Future Medicine, Samsung Medical Center, Seoul 06351, Korea.ORCID 0000-0002-6670-5500
Ye-Jin AnDepartment of Nursing, Heart Vascular Stroke Institute, Samsung Medical Center, Seoul 06351, Korea.ORCID 0000-0002-3099-9324
Jeong-Meen SeoDepartment of General Surgery, Division of Pediatric Surgery, Samsung Medical Center, Sungkyunkwan University of College of Medicine, Seoul 06351, Korea.ORCID 0000-0002-5527-3976
Samsung Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We evaluated the clinical reliability and utility of temperature measurements using no-contact forehead infrared thermometers (NCFITs) by comparing their temperature measurements with those obtained using infrared tympanic thermometers (IRTTs) in children. In this observational, prospective, and cross-sectional study, we enrolled 255 children (aged 1 month to 18 years) from the pediatric surgery ward at a tertiary medical center in Korea. The mean age of the children was 9.05 ± 5.39 years, and 54.9% were boys. The incidence rate of fever, defined as an IRTT reading of ≥38.0 °C, was 15.7%. The ICC coefficient for the assessment of agreement between temperatures recorded by the NCFIT and IRTT was 0.87, and the κ-coefficient was 0.83. The bias and 95% limits of agreement were 0.15 °C (−0.43 to 0.73). For an accurate diagnosis of fever (≥38 °C), the false-negative rate was much lower, but the false-positive rate was higher, especially in 6-year-old children. Therefore, NCFITs can be used to screen children for fever. However, a secondary check is required using another thermometer when the child’s temperature is >38 °C. NCFITs are proposed for screening but not for measuring the temperature. For the latter, an accurate and reliable thermometer shall be used.

Indexed as

body temperaturechildfeverinfrared raysthermometers

Identifiers

PMID36138700
PMCPMC9497495
OpenAlexW4296397017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.