Evidence map›Paper›PMID 36135246›Full record

ArticleGels (Basel, Switzerland)2022

PEDOT Composite with Ionic Liquid and Its Application to Deformable Electrochemical Transistors.

Sangkyu Lee, Jaepyo Jang, Sungjun Lee, Daekwang Jung, Mikyung Shin, Donghee Son

Open access · goldAbstract read
In one paragraph

Article in Gels (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Organic Electrochemical Transistors in Tissue-Interfaced Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Sangkyu LeeDepartment of Electrical and Computer Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.ORCID 0000-0003-0613-4846
Jaepyo JangDepartment of Electrical and Computer Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.
Sungjun LeeCenter for Bionics of Biomedical Research Institute, Korea Institute of Science and Technology, Seoul 02792, Korea.
Daekwang JungDepartment of Electrical and Computer Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.
Mikyung ShinCenter for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon 16419, Korea.ORCID 0000-0002-7990-5210
Donghee SonDepartment of Electrical and Computer Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Korea.ORCID 0000-0002-3772-8009
Institute for Basic Science · KRYonsei University · KR

Funding

ICT Creative Consilience program 2020-0-01821Institute for Basic Science IBS-R015-D1Institute of Information & Communications Technology Planning & Evaluation 2020-0-00261Korea Medical Device Development Fund 202012D28National Research Foundation of Korea 2020M3H2A1076786National Research Foundation of Korea 2020R1C1C1003903National Research Foundation of Korea 2020R1C1C1005567
6 · The paper itself

Abstract

Organic electrochemical transistors (OECTs) have become popular due to their advantages of a lower operating voltage and higher transconductance compared with conventional silicon transistors. However, current OECT platform-based skin-inspired electronics applications are limited due to the lack of stretchability in poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS). Some meaningful structural design strategies to resolve this limitation, including rendering OECT to make it more stretchable, have been reported. However, these strategies require complicated fabrication processes and face challenges due to the low areal density of active devices because wavy interconnect parts account for a large area. Nevertheless, there have been only a few reports of fully deformable OECT having skin-like mechanical properties and deformability. In this study, we fabricated stretchable and conductivity-enhanced channel materials using a spray-coating method after a composite solution preparation by blending PEDOT:PSS with several ionic liquids. Among these, the PEDOT composite prepared using 1-butyl-3-methylimidazolium octyl sulfate exhibited a better maximum transconductance value (~0.3 mS) than the other ion composites. When this material was used for our deformable OECT platform using stretchable Au nanomembrane electrodes on an elastomer substrate and an encapsulation layer, our d-ECT showed a barely degraded resistance value between the source and drain during 1000 cycles of a 30% repeated strain. We expect that our d-ECT device will serve as a step toward the development of more precise and accurate biomedical healthcare monitoring systems.

Indexed as

ionic liquidorganic electrochemical transistorPEDOT:PSSskin-inspired electronicsstretchable electronics

Identifiers

PMID36135246
PMCPMC9498364
OpenAlexW4293104195

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.