Evidence map›Paper›PMID 36134982›Full record

ArticleBioengineering (Basel, Switzerland)2022

A Multimodality Myocardial Perfusion Phantom: Initial Quantitative Imaging Results.

Marije E Kamphuis, Henny Kuipers, H Remco Liefers, Jan van Es, Frank F J Simonis, Marcel J W Greuter, Cornelis H Slump, Riemer H J A Slart

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Marije E KamphuisMultimodality Medical Imaging Group, Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands.
Henny KuipersRobotics and Mechatronics Group, Faculty of Electrical Engineering Mathematics and Computer Science, University of Twente, 7500 AE Enschede, The Netherlands.
H Remco LiefersDepartment of Radiology, Medisch Spectrum Twente, 7512 KZ Enschede, The Netherlands.
Jan van EsDepartment of Radiology, Medisch Spectrum Twente, 7512 KZ Enschede, The Netherlands.
Frank F J SimonisMagnetic Detection and Imaging Group, Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands.ORCID 0000-0002-0734-1778
Marcel J W GreuterRobotics and Mechatronics Group, Faculty of Electrical Engineering Mathematics and Computer Science, University of Twente, 7500 AE Enschede, The Netherlands.ORCID 0000-0001-5721-9159
Cornelis H SlumpRobotics and Mechatronics Group, Faculty of Electrical Engineering Mathematics and Computer Science, University of Twente, 7500 AE Enschede, The Netherlands.
Riemer H J A SlartDepartment of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, 9700 RB Groningen, The Netherlands.ORCID 0000-0002-5565-1164

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom's potential.

Indexed as

blood flowCTMRImultimodalitymyocardialperfusionPETphantomquantitative imaging

Identifiers

PMID36134982
PMCPMC9495397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.