ArticleCureus2022
External Ventricular Drain (EVD) Placement Using a Hands-On Training Session on a Simple Three-Dimensional (3D) Model.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Emerging Biomedical and Clinical Applications of 3D-Printed Poly(Lactic Acid)-Based Devices and Delivery Systems.Bioengineering (Basel, Switzerland) · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Neurosurgery is a demanding field with small margins of error within the operative field. Small errors can yield devastating consequences. Simulation has been proposed as a methodology for improving surgical skills within the neurosurgical realm. This study was conducted to investigate a novel realistic design for a clinical simulation based, low-cost alternative of external ventricular drain (EVD) placement, an essential basic neurosurgical procedure that is necessary for clinicians to master. A low-cost three-dimensional (3D) printed head using thermoplastic polylactic acid was designed with the tactile feedback of outer table, cancellous bone, and inner tables for drilling with replaceable frontal bones pieces for multi-use purposes. An agar gel filled with water was designed to simulate tactile passage through the cortex and into the ventricles. Neurosurgical and emergency resident physicians participated in a didactic session and then attempted placement of an EVD using the model to gauge the simulated model for accuracy and realism. Positioning, procedural time, and realism was evaluated. Improvements in procedural time and positioning were identified for both neurosurgical and emergency medicine (EM) residents. Catheter placement was within ideal position for all participants by the third attempt. All residents stated they felt more comfortable with placement with subsequent attempts. Neurosurgical residents subjectively noted similarities in tactile feedback during drilling compared to in-vivo. A low-cost realistic 3D printed model simulating basic neurosurgical procedures demonstrated improved procedural times and precision with neurosurgical and EM residents. Further, similarities between in-vivo tactile feedback and the low-cost simulation technology was noted. This low cost-model may be used as an adjunct for teaching to promote early procedural competency in neurosurgical techniques to promote learning without predisposition to patient morbidity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.