Evidence map›Paper›PMID 36134041›Full record

ArticleCureus2022

Radiation Monitoring Using Personal Dosimeter Devices in Terms of Long-Term Compliance and Creating a Culture of Safety.

Fahad Qureshi, Aarya Ramprasad, Bogdan Derylo

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Fahad QureshiSchool of Medicine, University of Missouri - Kansas City, Kansas City, USA.
Aarya RamprasadSchool of Medicine, University of Missouri - Kansas City, Kansas City, USA.
Bogdan DeryloDepartment of Nephrology, Vascular Access Centers, Chicago, USA.
University of Missouri–Kansas City · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Radiation-emitting devices are commonplace in the hospital with their ability to produce imaging for diagnoses, However, they hold a risk for device operators due to radiation exposure. Hospital systems have programs where physicians exposed to radiation are required to wear dosimeters to help record total radiation over time. Dosimetry readings over standardized recommendations can lead to hospital image issues and disciplinary action for physicians. This study aimed to discover the true values recorded on dosimeters with radiation exposure and discuss effective ways to encourage compliance with dosimeter usage. Methodology The study was completed over a course of 12 months with physicians from three different hospitals. Selection criteria included physicians considered to be "radiation workers" including those who operate x-ray machines, fluoroscopy units, unsealed and sealed isotopes, or those exposed to other sources of gamma or high-energy beta radiation. Two Plan-Do-Study-Act (PDSA) cycles were implemented. The first cycle was the first six months of the study and the second cycle was the second six months of the study. The first PDSA cycle had planned dosimeter reading check-ins every month. After this cycle ended, physicians were sent a survey anonymously asking if they had ever intentionally left behind their dosimeter. In the second PDSA cycle, a planned policy change was put into action where penalties for physicians who went over the recommended dosage were stopped. A monthly educational meeting where a discussion on the risks of radiation as well as protective mechanisms was implemented instead. The same monthly check-ins for dosimeter reading monitoring were employed again with the same survey regarding dosimeter adherence and usage being sent out at the end of the second cycle. Run charts were created to determine whether the policy change showed statistically significant differences in dosimetry readings. Results Protocol changes led to statistically significant (p<0.05) differences in radiation exposure recorded throughout the hospital systems. The primary PDSA cycle readings showed that hospital systems one (n=118), two (n=71), and three (n=32) had readings of 3.90 mSv, 2.55 mSv, and 2.02 mSv, respectively, which were all under the annual recommended dose limit of 10 mSv maximum per six months. However, an average of 94.4% (n=221) of physicians across all hospitals admitted to not using the dosimeter. In the second PDSA cycle after the policy change, the radiation doses were higher with an increase in the average cumulative dose at hospital system one of 255%, 328% at system two, and 323% at system three. Hospital systems one and two were both over the yearly limit of 20.0 mSv (7.70 mSv over for system one and 1.86 mSv over for system two) while system three remained under. The number of physicians who stated they always used the dosimeter during the second PDSA cycle increased to 83.9% in-hospital system one, 90.2% in-hospital system two, and 93.8% in-hospital system three. Conclusion Creating a culture of safety is critical for physician compliance. A comfortable work environment without unreasonable consequences creates an environment where physicians can focus on their health and safety while also doing what is in the workplace's best interest. This culture can best be made with more collaboration between administrative staff and workers to create a trustworthy experience in hospital systems.

Indexed as

dosimeter usagegeneral radiologyoccupational healthquality improvementradiation monitoring

Identifiers

PMID36134041
PMCPMC9469909
OpenAlexW4291327370

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.