Evidence map›Paper›PMID 36132344›Full record

ArticleNanoscale advances2021

Ultrabright fluorescent nanothermometers.

V Kalaparthi, B Peng, S A M A Peerzade, S Palantavida, B Maloy, M E Dokukin, I Sokolov

Abstract read
In one paragraph

Article in Nanoscale advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Single-Molecule Vibrational Thermometry.The journal of physical chemistry. B · 2025
    Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

V KalaparthiDepartment of Mechanical Engineering, Department of Biomedical Engineering, Tufts University 200 College Ave. Medford MA 02155 USA igor.sokolov@tufts.edu.
B PengDepartment of Biomedical Engineering 4 Colby Str. Medford MA 02155 USA.
S A M A PeerzadeDepartment of Biomedical Engineering 4 Colby Str. Medford MA 02155 USA.
S PalantavidaDepartment of Mechanical Engineering, Department of Biomedical Engineering, Tufts University 200 College Ave. Medford MA 02155 USA igor.sokolov@tufts.edu.ORCID https://orcid.org/0000-0002-6159-897X
B MaloyDepartment of Physics, Tufts University 547 Boston Ave. Medford MA 02155 USA.ORCID https://orcid.org/0000-0002-9149-2981
M E DokukinDepartment of Mechanical Engineering, Department of Biomedical Engineering, Tufts University 200 College Ave. Medford MA 02155 USA igor.sokolov@tufts.edu.
I SokolovDepartment of Mechanical Engineering, Department of Biomedical Engineering, Tufts University 200 College Ave. Medford MA 02155 USA igor.sokolov@tufts.edu.ORCID https://orcid.org/0000-0001-6260-4326

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here we report on the first ultrabright fluorescent nanothermometers, ∼50 nm-size particles, capable of measuring temperature in 3D and down to the nanoscale. The temperature is measured through the recording of the ratio of fluorescence intensities of fluorescent dyes encapsulated inside the nanochannels of the silica matrix of each nanothermometer. The brightness of each particle excited at 488 nm is equivalent to the fluorescence coming from 150 molecules of rhodamine 6G and 1700 molecules of rhodamine B dyes. The fluorescence of both dyes is excited with a single wavelength due to the Förster resonance energy transfer (FRET). We demonstrate repeatable measurements of temperature with the uncertainty down to 0.4 K and a constant sensitivity of ∼1%/K in the range of 20-50 °C, which is of particular interest for biomedical applications. Due to the high fluorescence brightness, we demonstrate the possibility of measurement of accurate 3D temperature distributions in a hydrogel. The accuracy of the measurements is confirmed by numerical simulations. We further demonstrate the use of single nanothermometers to measure temperature. As an example, 5-8 nanothermometers are sufficient to measure temperature with an error of 2 K (with the measurement time of >0.7 s).

Identifiers

PMID36132344
PMCPMC9418727

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked