Evidence map›Paper›PMID 36132074›Full record

ArticleBioMed research international2022

Volume Fluctuations in Active and Nonactive Transtibial Prosthetics Users.

Nur Afiqah Hamzah, Nasrul Anuar Abd Razak, Mohd Sayuti Ab Karim, Siti Zuliana Salleh

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Nur Afiqah HamzahDepartment of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
Nasrul Anuar Abd RazakDepartment of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.ORCID https://orcid.org/0000-0002-1911-015X
Mohd Sayuti Ab KarimDepartment of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
Siti Zuliana SallehDepartment of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
University of Malaya · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to evaluate the validity and reliability of the Biosculptor's Bioscanner system in capturing transtibial residual limb volume fluctuations in active and nonactive amputees during walking activity. Residual limb volume was obtained by measuring the limb circumference after amputees walked for 5 to 25 minutes for five consecutive days. The comparison of mean circumference between Bioscanner and manual measurements (i.e., tape measure) showed that the Bioscanner gave a higher estimation of circumference for the different amputees. Short-term changes in girth and volume due to an activity such as walking do not fluctuate uniformly. The results reflected as such as nonconsistence circumference change identified at different locations of the circumference profiles. Both amputees experienced a significant increase in circumference at the distal end of the limbs after 5 minutes of walking (7.35% change in nonactive and 8.83% in active amputees), and the measurement decreased as amputees walked longer. At 4-8 cm below the mid-patella tendon (pressure tolerant areas), both amputees experienced minor changes in the size of their circumference. The residual limb volume calculation resulted in the percentage difference between the two methods ranging from 2.4% to 9.3%. Pearson coefficient correlation obtained showed a high correlation between the two techniques, ranging from 0.97 to 1. The analysis of the limit of agreements showed that the majority of measurements were closed to the mean, suggesting that Bioscanner and manual techniques may be interchangeable and agree with one another. This study has implied that Bioscanner is comparable to the standard measurement method and may serve as an alternative tool in managing daily residual limb volume change.

Indexed as

AmputeesArtificial LimbsHumansProsthesis DesignReproducibility of ResultsWalking

Identifiers

PMID36132074
PMCPMC9484881
OpenAlexW4295880348

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.