Evidence map›Paper›PMID 36129744›Full record

ArticleActa bio-medica : Atenei Parmensis2022

Late intraprosthetic dislocation of a monoblock dual-mobility cup cemented into a well-fixed cementless acetabular shell. A case report.

Maurizio Ulgelmo, Andrea Sandri, Dario Regis, Edoardo Casablanca, Giovanna Toso, Roberto Valentini, Bruno Magnan

Open access · greenAbstract readCase Reports
In one paragraph

Article in Acta bio-medica : Atenei Parmensis, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 78% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Maurizio Ulgelmoa:1:{s:5:"en_US";s:33:"Università degli Studi di Verona";}. maurizio.ulgelmo@studenti.univr.it.
Andrea SandriUniversità degli Studi di Verona. andrea.sandri@aovr.veneto.it.
Dario RegisUniversità degli Studi di Verona. dario.regis@aovr.veneto.it.
Edoardo CasablancaUniversità degli Studi di Verona. edoardo.casablanca@studenti.univr.it.
Giovanna TosoAzienda ULSS n. 6 Euganea - Ospedale Civile di Cittadella. giovannatoso.1@gmail.com.
Roberto ValentiniUniversità degli Studi di Verona. roberto.valentini@univr.it.
Bruno MagnanUniversità degli Studi di Verona. bruno.magnan@univr.it.
University of Verona · ITAzienda USL di Bologna · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraprosthetic dislocation (IPD) is a specific implant-related complication of dual mobility (DM) implants, which is defined as a dissociation of polyethylene (PE) liner from the femoral head. We report a unique case of  late IPD of a monoblock DM cup cemented into a well-fixed cementless acetabular shell for recurrent dislocation of total hip arthroplasty (THA). A 77-year-old woman was admitted to our department for acute right hip pain, functional impairment and inability to bear weight without any trauma. Three years earlier, she underwent revision THA for recurrent dislocation with a monoblock DM cup cemented into a well-fixed cementless acetabular shell according to the "double-socket" technique. Three months after that revision the patient experienced an anterior THA dislocation, which was managed by closed reduction under sedation in the emergency room. No additional episodes of prosthesis instability occurred. Upon admission, radiographic evaluation showed  right THA dislocation. X-rays performed  after closed reduction revealed eccentric positioning of the head inside the cup, and a direct contact between the metal head and the cup was revealed by subsequent CT scan, confirming the suspicion of IPD. The patient underwent revision surgery, during which the PE liner was found lodged within the cup in a subluxated position, disassembled from the inner head. Both the acetabular cup and modular femoral stem proved well-fixed and impossible to remove, therefore they were retained. The explanted DM components were replaced with new ones of the same size and, thanks to the femoral neck's modular nature, it was substituted with a longer one, which resulted in improved stability against intraoperative stress maneuvers. The postoperative course was uncomplicated. At 1-year follow-up, the patient had a good functional recovery.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisJoint DislocationsAcetabulumAgedFemaleFollow-Up StudiesHumansPolyethylenePostoperative ComplicationsProsthesis DesignProsthesis FailureReoperationRetrospective StudiesPolyethylene

Identifiers

PMID36129744
PMCPMC10510970
OpenAlexW4296798712

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.