ArticleAnalytical chemistry2022
Additively Manufactured Rotating Disk Electrodes and Experimental Setup.
Article in Analytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Expanding the Toolbox of Multi-Material Three-Dimensional-Printed Electrochemical Flow Cells Fabricated in a Single Step: Impinging Jet, Mixing and Dilution, and Dual-Electrode Generator-Collector Electrochemical Cells.ACS electrochemistry · 2026Article
- Additive Manufacturing of Customized Flexible Wearable Sensors for Sweat Analysis with Bespoke, Low-Cost Conductive TPU.ACS measurement science au · 2025Article
- Upcycling Hospital Lab Polypropylene Waste into a Fully Integrated Additive Manufacturing Electroanalytical Sensing Platforms.ACS sustainable resource management · 2025Article
- Article
- The Current Shortcomings and Future Possibilities of 3D Printed Electrodes.Analytical chemistry · 2024Review
- Optimised graphite/carbon black loading of recycled PLA for the production of low-cost conductive filament and its application to the detection of β-estradiol in environmental samples.Mikrochimica acta · 2024Article
- Recycled PETg embedded with graphene, multi-walled carbon nanotubes and carbon black for high-performance conductive additive manufacturing feedstock.RSC advances · 2024Article
- Mixed Graphite/Carbon Black Recycled PLA Conductive Additive Manufacturing Filament for the Electrochemical Detection of Oxalate.Analytical chemistry · 2023Article
- Circular Economy Electrochemistry: Recycling Old Mixed Material Additively Manufactured Sensors into New Electroanalytical Sensing Platforms.ACS sustainable chemistry & engineering · 2023Article
- Electroanalytical Overview: The Determination of Levodopa (L-DOPA).ACS measurement science au · 2023Review
- Circular Economy Electrochemistry: Creating Additive Manufacturing Feedstocks for Caffeine Detection from Post-Industrial Coffee Pod Waste.ACS sustainable chemistry & engineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This manuscript details the first report of a complete additively manufactured rotating disk electrode setup, highlighting how high-performing equipment can be designed and produced rapidly using additive manufacturing without compromising on performance. The additively manufactured rotating disk electrode system was printed using a predominantly acrylonitrile butadiene styrene (ABS) based filament and used widely available, low-cost electronics, and simplified machined parts to create. The additively manufactured rotating disk electrode system costs less than 2% of a comparable commercial solution (£84.47 ($102.26) total). The rotating disk electrode is also additively manufactured using a carbon black/polylactic acid (CB/PLA) equivalent, developing a completely additively manufactured rotating disk electrode system. The electrochemical characterization of the additively manufactured rotating disk electrode setup was performed using hexaamineruthenium(III) chloride and compared favorably with a commercial glassy carbon electrode. Finally, this work shows how the additively manufactured rotating disk electrode experimental system and additive manufactured electrodes can be utilized for the electroanalytical determination of levodopa, a drug used in the treatment of Parkinson's disease, producing a limit of detection of 0.23 ± 0.03 μM. This work represents a step-change in how additive manufacturing can be used in research, allowing the production of high-end equipment for hugely reduced costs, without compromising on performance. Utilizing additive manufacturing in this way could greatly enhance the research possibilities for less well-funded research groups.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.