Evidence map›Paper›PMID 36126073›Full record

ArticlePloS one2022

Decontamination of Geobacillus Stearothermophilus using the Arca Aerosolized Hydrogen Peroxide decontamination system.

Loren Benjamin Mead, Tanner Mathison, Garry Osborne, Anne Marie Richards

Open access · goldAbstract readControlled Clinical Trial
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Loren Benjamin MeadAbaton, Board of Directors, Washington, D.C, United States of America.ORCID 0000-0003-2430-1468
Tanner MathisonAbaton, Board of Directors, Washington, D.C, United States of America.
Garry OsborneAbaton, Board of Directors, Washington, D.C, United States of America.
Anne Marie RichardsAbaton, Board of Directors, Washington, D.C, United States of America.
The University of Texas Health Science Center at Houston · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn response to the limited supply of personal protective equipment during the pandemic caused by SARS-CoV-2, recent studies demonstrate that gaseous H2O2 is an effective decontaminant of N95 filtering facepiece respirators to enable reuse of these items in a clinical setting. This paper evaluates the efficacy of the Arca Aerosolized Hydrogen Peroxide Decontamination System (Arca), a novel aerosolized H2O2 decontamination system, using biologic indicator testing. MATERIALS AND

methodsThe Arca produces and circulates H2O2 aerosol inside of a sealed stainless steel chamber. The Arca's decontamination efficacy was evaluated in 8 decontamination trials with 2 H2O2 concentrations (3% and 12%) and 4 decontamination cycle durations (45, 60, 90, and 120 minutes). Efficacy was evaluated by testing: 1) the concentration in parts per million (ppm) of H2O2 produced inside the chamber and the concentration in ppm of H2O2 vented from the chamber, and 2) the decontamination of Mesa Biologic Indicator filter strips (BI) inoculated with Geobacillus Stearothermophilus. Control tests were conducted by submerging BI strips in 3mL of 3% and 12% H2O2 for 120 minutes (negative controls) and by not exposing one BI strip to H2O2 (positive control).

resultsGreater than 5000 ppm of H2O2 was detected on the concentration strips inside the chamber for each of the eight decontamination trials. No vented H2O2 was detected on the external concentration strips after any decontamination trial. No growth was observed for any of the negative controls after seven days. The positive control was positive for growth.

conclusionThe Arca Aerosolized Hydrogen Peroxide Decontamination System is effective at decontaminating bacterial G. Stearothermophilus at a cycle time of 45 minutes utilizing 6mL of 3% H2O2 solution.

Indexed as

Biological ProductsCOVID-19DisinfectantsDecontaminationGeobacillus stearothermophilusHumansHydrogen PeroxideRespiratory Aerosols and DropletsSARS-CoV-2Stainless SteelBiological ProductsDisinfectantsHydrogen PeroxideStainless Steel