ArticleCureus2022
Aneurysm Perforation Due to Advancement of the Coil Delivery Wire During Stent-Assisted Embolization.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We report a case of intraprocedural aneurysm rupture during coil embolization caused by a coil delivery wire. A 68-year-old woman underwent stent-assisted coil embolization for an unruptured aneurysm in the internal carotid artery (ICA). A low profile visible intraluminal support device was deployed at the aneurysm neck. Coil embolization was performed with a jailing technique. After deflection of the jailed microcatheter was released, a coil was placed in the aneurysm against resistance to coil insertion. The movement of the microcatheter tip was restricted with the stent. A coil delivery wire that was advanced after coil detachment perforated the aneurysm. Hemostasis was achieved, and coil embolization was finished with a slight neck remnant. Complete occlusion of the aneurysm was confirmed on angiography six months later. Advancement of a coil alignment marker after coil detachment may cause aneurysm perforation due to coil delivery wire advancement. In stent-assisted coil embolization, when the movement of the microcatheter tip in the aneurysm is restricted by the stent and there is resistance to coil insertion, the risk of perforation due to the coil delivery wire after coil detachment should be noted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.