Evidence map›Paper›PMID 36120011›Full record

ArticleACS omega2022

DNA Antiadhesive Layer for Reusable Plasmonic Sensors: Nanostructure Pitch Effect.

Remigiusz K Trojanowicz, Ambra Vestri, Massimo Rippa, Joseph Zyss, Katarzyna Matczyszyn, Lucia Petti

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Remigiusz K TrojanowiczAdvanced Materials Engineering and Modelling Group, Faculty of Chemistry, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland.
Ambra VestriInstitute of Applied Sciences and Intelligent Systems "E. Caianiello" of CNR, 80072 Pozzuoli, Italy.ORCID https://orcid.org/0000-0001-9877-7341
Massimo RippaInstitute of Applied Sciences and Intelligent Systems "E. Caianiello" of CNR, 80072 Pozzuoli, Italy.
Joseph ZyssLUMIN Laboratory and Institut d'Alembert, Ecole Normale Supérieure Paris-Saclay, CNRS, Université Paris-Saclay, 4, avenue des Sciences, 91190 Gif-sur-Yvette, France.
Katarzyna MatczyszynAdvanced Materials Engineering and Modelling Group, Faculty of Chemistry, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland.ORCID https://orcid.org/0000-0001-8578-8340
Lucia PettiInstitute of Applied Sciences and Intelligent Systems "E. Caianiello" of CNR, 80072 Pozzuoli, Italy.
Institute of Applied Science and Intelligent Systems · ITWrocław University of Science and Technology · PLÉcole Normale Supérieure Paris-Saclay · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A long-term reusable sensor that provides the opportunity to easily regenerate the active surface and minimize the occurrence of undesired absorption events is an appealing solution that helps to cut down the costs and improve the device performances. Impressive advances have been made in the past years concerning the development of novel cutting-edge sensors, but the reusability can currently represent a challenge. Direct shielding of the sensor surface is not always applicable, because it can impact the device performance. This study reports an antiadhesive layer (AAL) made of 90 mg/mL DNA sodium salt from salmon testes (ssstDNA) for passivating gold plasmonic sensor surfaces. Our gold two-dimensional (2D) nanostructured plasmonic metasurfaces modified with AAL were used for DNA quantification. AAL is thin enough that the plasmonic sensor remains sensitive to subsequent deposition of DNA, which serves as an analyte. AAL protects the gold surface from unwanted nonspecific adsorption by enabling wash-off of the deposited analyte after analysis and thus recovery of the LSPR peak position (rLSPR). The calibration curve obtained on a single nanostructure (Achiral Octupolar, 100 nm pitch) gave an LOD = 105 ng/mL and an extraordinary dynamic range, performances comparable or superior to those of commercial UV-vis spectrometers for acid nucleic dosage. Two different analytes were tested: ssstDNA (∼2000 bp) in deionized water and double-strand DNA (dsDNA) of 546-1614 bp in 100 mM Tris buffer and 10 mM MgCl

Identifiers

PMID36120011
PMCPMC9475616
OpenAlexW4293706606

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.