3D-printed bolus ensures the precise postmastectomy chest wall radiation therapy for breast cancer.

Xiran Wang, Jianling Zhao, Zhongzheng Xiang, Xuetao Wang, Yuanyuan Zeng, Ting Luo, Xi Yan, Zhuang Zhang, Feng Wang, Lei Liu

Open access · goldAbstract read
In one paragraph

Article in Frontiers in oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Review
  6. Clinical application of 3D-printed bolus in postmastectomy radiotherapy.Journal of applied clinical medical physics · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Application of 3D printing for personalized boluses in radiotherapy: a systematic review.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2025
    Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Xiran WangDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Jianling ZhaoDepartment of Radiotherapy, West China Hospital, Sichuan University, Chengdu, China.
Zhongzheng XiangDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Xuetao WangDepartment of Radiotherapy, West China Hospital, Sichuan University, Chengdu, China.
Yuanyuan ZengDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Ting LuoDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Xi YanDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Zhuang ZhangState Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
Feng WangDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
Lei LiuDepartment of Head and Neck and Mammary Oncology, West China Hospital, Sichuan University, Chengdu, China.
West China Hospital of Sichuan University · CNSichuan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the values of a 3D-printed bolus ensuring the precise postmastectomy chest wall radiation therapy for breast cancer. Methods and materials: In the preclinical study on the anthropomorphic phantom, the 3D-printed bolus was used for dosimetry and fitness evaluation. The dosimetric parameters of planning target volume (PTV) were assessed, including D Results: In preclinical studies, a 3D-printed bolus can better ensure the radiation coverage of PTV (HI 0.05, CI 99.91%), the dose accuracy (|%diff| 0.99%), and skin fitness (mean air gap 1.01 mm). Of the 27 eligible patients, we evaluated the radiation dose parameter (median(min-max): D Conclusion: A 3D-printed bolus can guarantee the precise radiation dose on skin surface, good fitness to skin, and controllable acute skin toxicity, which possesses a great clinical application value in postmastectomy chest call radiation therapy for breast cancer.

Indexed as

3D-printed bolusbreast cancerdosimetryPMRTradiation dermatitis

Identifiers

PMID36119487
PMCPMC9478602
OpenAlexW4294190564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.