ArticleBMC musculoskeletal disorders2022
Fully automated measurement on coronal alignment of lower limbs using deep convolutional neural networks on radiographic images.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Precision of AI-Based Lower Limb Assessment in Children and Adolescents with Open Growth Plates.Diagnostics (Basel, Switzerland) · 2026Article
- An artificial intelligence framework for universal landmark matching and morphometry in musculoskeletal radiography.European radiology · 2026Article
- Artificial intelligence in orthopedics: current applications, challenges, and future directions.Knee surgery & related research · 2026Review
- Measurement and analysis of standing spine-pelvis-lower limb biomechanical parameters in patients with knee osteoarthritis based on principal component analysis.Frontiers in bioengineering and biotechnology · 2026Article
- Automated radiographic assessment of lower limb alignment using deep learning in a data-constrained clinical setting.BMC musculoskeletal disorders · 2025Article
- High accuracy in lower limb alignment analysis using convolutional neural networks, with improvements needed for joint-level metrics.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
- Coronal lumbar horizontal shift and lower limb force line in patients with knee osteoarthritis: a correlation study.Frontiers in bioengineering and biotechnology · 2025Review
- Can Artificial Intelligence Reliably and Accurately Measure Lower Limb Alignment: A Systematic Review and Meta-Analysis.The archives of bone and joint surgery · 2025Review
- Automated analysis of knee joint alignment using detailed angular values in long leg radiographs based on deep learning.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA deep convolutional neural network (DCNN) system is proposed to measure the lower limb parameters of the mechanical lateral distal femur angle (mLDFA), medial proximal tibial angle (MPTA), lateral distal tibial angle (LDTA), joint line convergence angle (JLCA), and mechanical axis of the lower limbs.
methodsStanding X-rays of 1000 patients' lower limbs were examined for the DCNN and assigned to training, validation, and test sets. A coarse-to-fine network was employed to locate 20 key landmarks on both limbs that first recognised the regions of hip, knee, and ankle, and subsequently outputted the key points in each sub-region from a full-length X-ray. Finally, information from these key landmark locations was used to calculate the above five parameters.
resultsThe DCNN system showed high consistency (intraclass correlation coefficient > 0.91) for all five lower limb parameters. Additionally, the mean absolute error (MAE) and root mean squared error (RMSE) of all angle predictions were lower than 3° for both the left and right limbs. The MAE of the mechanical axis of the lower limbs was 1.124 mm and 1.416 mm and the RMSE was 1.032 mm and 1.321 mm, for the right and left limbs, respectively. The measurement time of the DCNN system was 1.8 ± 1.3 s, which was significantly shorter than that of experienced radiologists (616.8 ± 48.2 s, t = -180.4, P < 0.001).
conclusionsThe proposed DCNN system can automatically measure mLDFA, MPTA, LDTA, JLCA, and the mechanical axis of the lower limbs, thus helping physicians manage lower limb alignment accurately and efficiently.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.