Identifying fragile calcifications of the aortic valve in transcatheter aortic valve replacement: iodine concentration of aortic valvular calcification by spectral CT.
Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Multi-DECT image-based radiomics with interpretable machine learning for preoperative prediction of tumor budding grade and prognosis in colorectal cancer: a dual-center study.Abdominal radiology (New York) · 2026Article
- Aortic Valve Calcium Score: Applications in Clinical Practice and Scientific Research-A Narrative Review.Journal of clinical medicine · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 2 countries.
Funding
Abstract
objectiveTo demonstrate the relationship between spectral computed tomography (CT) measured iodine concentration and strength of aortic valvular calcification (AVC) in patients with aortic valve stenosis (AVS).
methodsA retrospective study was performed on patients who underwent transcatheter aortic valve replacement (TAVR) for symptomatic AVS and underwent both pre and postprocedural electrocardiogram gated CT scans using a spectral CT system. Preprocedural CT was used to evaluate the volume and iodine concentration (IC) in the AVC. Postprocedural CT data were used to calculate the volume reduction percentage (VRP) of AVC. Multiple linear regression analysis was used to identify the independent variables related to the VRP in AVCs.
resultsA total of 94 AVCs were selected from 22 patients. The mean volume and IC of the AVCs before TAVR were 0.37 mL ± 0.15 mL and 7 mg/mL ± 10.5 mg/mL, respectively. After TAVR, a median VRP of all 94 AVCs was 18.5%. Multiple linear regression analysis showed that the IC was independently associated with the VRP (coefficient = 1.64, p < 0.001). When an optimal IC cutoff point was set at 4 mg/mL in the assessment of a fragile AVC which showed the VRP was > 18.5%, the sensitivity was 63%; specificity, 91%; positive predictive value, 88%; and negative predictive value, 71%.
conclusionsWhen using spectral CT to prepare the TAVR, measuring the IC of the AVC may be useful to assess the probability of AVC deformity after TAVR. KEY POINTS: • A dual-layer detector-based spectral CT enables quantifying iodine of contrast media in the aortic valve calcification (AVC) on contrast-enhanced CT images. • The AVC including iodine of contrast media on contrast-enhanced CT image may have loose compositions, associated with the deformity of AVC after TAVR. • Measuring the iodine concentration in AVC may have the potential to assess the probability of AVC deformity, which may be associated with the outcome and complications after TAVR.2.