Evidence map›Paper›PMID 36111031›Full record

ArticleAnnals of translational medicine2022

Application of metal artifact reduction software in gemstone spectral computed tomography for patients after total knee arthroplasty.

Jinge Zhang, Xiaozhou Wang, Fei Zhao, Kai Zhang, Yuming Li, Yu Zhang, Yi Zeng, Chunchao Xia, Zhenlin Li

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 53% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Jinge ZhangDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Xiaozhou WangDepartment of Radiology, Meishan People's Hospital, Meishan, China.
Fei ZhaoDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Kai ZhangDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Yuming LiDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Yu ZhangDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Yi ZengDepartment of Orthopedics, West China Hospital, Sichuan University, Chengdu, China.
Chunchao XiaDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Zhenlin LiDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Sichuan University · CNWest China Hospital of Sichuan University · CNMeizhou City People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: To explore the feasibility and effectiveness of the metal artifact reduction software (MARs) reconstruction algorithm in reducing metal artifacts of knee prostheses and to explore the optimal monochromatic level of virtual monochromatic spectral (VMS) images for artifact reduction to provide high-quality images and reliable diagnosis in patients after total knee arthroplasty (TKA). Methods: A total of 31 patients underwent gemstone spectral computed tomography. VMS images with MARs and without MARs were obtained at different energy levels (80, 100, 120, and 140 keV). Two observers scored each group of images, and interobserver agreement was evaluated. Artificial indices (AIs), percentage Results: The consistency of the scores of the 2 observers was good (kappa value =0.78), and the score of the VMS images with MARs was higher than that of VMS images without MARs. AI values and percentage Conclusions: VMS images combined with the MARs algorithm can significantly reduce the metal artifacts of knee prostheses and improve image quality. At an energy level of 100-120 keV, a good metal artifact removal effect and soft tissue contrast can be achieved, and the best metal artifact removal effect can be achieved at 140 keV.

Indexed as

dual-energy computed tomography (dual-energy CT)Gemstone spectral computed tomography (gemstone spectral CT)metal artifacttotal knee arthroplasty (TKA)

Identifiers

PMID36111031
PMCPMC9469117
OpenAlexW4289816270

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.