ArticleFrontiers in bioengineering and biotechnology2022
Deterioration of the fixation segment's stress distribution and the strength reduction of screw holding position together cause screw loosening in ALSR fixed OLIF patients with poor BMD.
Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 30 citations in OpenAlex.
- Bone density-optimized pedicle screw planning enhances mechanical stability.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Establishment and Validation of a Risk Prediction Model for the Superior Cluneal Nerve Entrapment Neuropathy after Thoracic or Lumbar Fracture: A Case-Comparative Study.Journal of pain research · 2026Article
- Single-Side Iatrogenic Pedicle Injury May Trigger an Increased Risk of Contralateral Screw Loosening: An In Silico Study.JOR spine · 2025Article
- Risk factors for pedicle screw loosening: a comprehensive review.Journal of orthopaedic surgery and research · 2025Review
- Predictive value of Hounsfield units and vertebral bone quality on cage subsidence in oblique lateral interbody fusion with bilateral posterior fixation.Journal of orthopaedic surgery and research · 2025Article
- Poor bony density can independently trigger higher incidence of adjacent vertebral fracture after percutaneous vertebralplasty: a mono-center retrospective study.Langenbeck's archives of surgery · 2025Article
- Article
- An OLIF Cage Integrated with a Low-Profile Plate and Cross Screws Could Reduce the Risk of Postoperative Complications Biomechanically.Annals of biomedical engineering · 2025Article
- The Bony Density of the Pedicle Plays a More Significant Role in the Screw Anchorage Ability Than Other Regions of the Screw Trajectory.Orthopaedic surgery · 2025Article
- Biomechanical effects of screw loosening after lumbar PEEK rod and titanium rod fixation: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- Impact of screw tip design on screw anchorage: mechanical testing and numerical simulation.Journal of orthopaedic surgery and research · 2024Article
- Changes in nail position and antirotation blade angles on the risk of femoral head varus in PFNA fixed patients: a clinical review and comprehensive biomechanical research.European journal of medical research · 2024Article
- Extending the intermedullary nail will not reduce the potential risk of femoral head varus in PFNA patients biomechanically: a clinical review and corresponding numerical simulation.BMC musculoskeletal disorders · 2024Review
- Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.European journal of medical research · 2024Article
- Intraoperative capsule protection can reduce the potential risk of adjacent segment degeneration acceleration biomechanically: an in silico study.Journal of orthopaedic surgery and research · 2024Article
- Anterior direct decompression significantly relieves spinal cord high signal in patients with ossification of the posterior longitudinal ligament: a case-control study.Journal of orthopaedic surgery and research · 2023Article
- Nucleus high intensity in the T2-weighted MRI is a potential predictor of annulus tear in cervical injured patients: a case comparative study.BMC musculoskeletal disorders · 2023Article
- Fixation-induced surgical segment's high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations.Journal of orthopaedic surgery and research · 2023Article
- Incomplete insertion of pedicle screws triggers a higher biomechanical risk of screw loosening: mechanical tests and corresponding numerical simulations.Frontiers in bioengineering and biotechnology · 2023Article
- Stepwise reduction of bone mineral density increases the risk of cage subsidence in oblique lumbar interbody fusion patients biomechanically: an in-silico study.BMC musculoskeletal disorders · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The vertebral body's Hounsfield unit (HU) value can credibly reflect patients' bone mineral density (BMD). Given that poor bone-screw integration initially triggers screw loosening and regional differences in BMD and strength in the vertebral body exist, HU in screw holding planes should better predict screw loosening. According to the stress shielding effect, the stress distribution changes in the fixation segment with BMD reduction should be related to screw loosening, but this has not been identified. We retrospectively collected the radiographic and demographic data of 56 patients treated by single-level oblique lumbar interbody fusion (OLIF) with anterior lateral single rod (ALSR) screw fixation. BMD was identified by measuring HU values in vertebral bodies and screw holding planes. Regression analyses identified independent risk factors for cranial and caudal screw loosening separately. Meanwhile, OLIF with ALSR fixation was numerically simulated; the elastic modulus of bony structures was adjusted to simulate different grades of BMD reduction. Stress distribution changes were judged by computing stress distribution in screws, bone-screw interfaces, and cancellous bones in the fixation segment. The results showed that HU reduction in vertebral bodies and screw holding planes were independent risk factors for screw loosening. The predictive performance of screw holding plane HU is better than the mean HU of vertebral bodies. Cranial screws suffer a higher risk of screw loosening, but HU was not significantly different between cranial and caudal sides. The poor BMD led to stress concentrations on both the screw and bone-screw interfaces. Biomechanical deterioration was more severe in the cranial screws than in the caudal screws. Additionally, lower stress can also be observed in fixation segments' cancellous bone. Therefore, a higher proportion of ALSR load transmission triggers stress concentration on the screw and bone-screw interfaces in patients with poor BMD. This, together with decreased bony strength in the screw holding position, contributes to screw loosening in osteoporotic patients biomechanically. The trajectory optimization of ALSR screws based on preoperative HU measurement and regular anti-osteoporosis therapy may effectively reduce the risk of screw loosening.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.