Characterization of left atrial assist device implantation: Early results of ex vivo anatomical assessment.

Chihiro Miyagi, Kiyotaka Fukamachi, Takuma Miyamoto, Barry D Kuban, Randall C Starling, Jamshid H Karimov

Abstract read
In one paragraph

Article in Artificial organs, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chihiro MiyagiDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0001-8986-2499
Kiyotaka FukamachiDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0002-4852-8416
Takuma MiyamotoDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Barry D KubanDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Randall C StarlingDepartment of Cardiovascular Medicine, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Jamshid H KarimovDepartment of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.ORCID https://orcid.org/0000-0002-0167-0415

Funding

Ohio Third Frontier (The State of Ohio, Department of Development) TVSF19-0436
6 · The paper itself

Abstract

backgroundThe left atrial assist device (LAAD) is a novel pump that was developed specifically for the treatment of heart failure with preserved ejection fraction. The device is surgically implanted in the mitral position. This study aimed to characterize the various device-fitting configurations in the mitral annular position.

methodsRapidly prototyped LAAD models (n = 5) were fabricated with five different driveline configurations: (A) annulus level/intra-cuff running; (B) supra-cuff/below coronary sinus (CS); (C) infra-cuff; (D) supra-annulus/supra-CS; (E) left ventricular free wall level. The 3D-printed models were implanted in extracted fresh porcine hearts (80-100 kg, adult, healthy porcine) and the proximity of anatomical structures between the driveline and CS and coronary artery (CA) were measured.

resultsAll five device configurations were evaluated for fitting. For the purpose of preventing blood clot formation around the driveline, the mitral annulus (MA) as a driveline pass-way (configuration A) has been considered advantageous with the current device, in that the driveline exposure to blood has been avoided. The CS does not exist at exactly the same level as the MA, and there is less risk of injuring it than using the left atrial free wall. However, there is an inevitable risk of damaging the CA, so careful visual inspection before inserting the driveline is needed.

conclusionsSeveral options of driveline exteriorization were demonstrated, and the safety of each configuration was evaluated. Using the MA as a pathway for the driveline exit is considered to be a reasonable and safe method.

Indexed as

Atrial AppendageHeart-Assist DevicesHeart FailureAnimalsHeart AtriaHeart VentriclesMitral ValveSwineatrioventricular groovedevice therapyfitting studyheart failureleft atrial assistancemechanical circulatory support

Identifiers

PMID36106370
PMCPMC10086780

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.