Evidence map›Paper›PMID 36105412›Full record

ArticleResuscitation plus2022

A survey of the incidence of defibrillator damage during double sequential external defibrillation for refractory ventricular fibrillation.

Ian R Drennan, Dustin Seidler, Sheldon Cheskes

Open access · goldAbstract read
In one paragraph

Article in Resuscitation plus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.6field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Ian R DrennanSunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
Dustin SeidlerToronto Paramedic Service, Toronto, ON, Canada.
Sheldon CheskesUniversity of Toronto, Department of Family and Community Medicine, Division of Emergency Medicine, Toronto, ON, Canada.
University of Toronto · CAToronto Metropolitan University · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Double Sequential External Defibrillation (DSED) is a proposed treatment strategy for patients in refractory VF (RVF) during out-of-hospital cardiac arrest (OHCA). Defibrillator damage employing DSED is a theoretical concern expressed by defibrillator manufacturers yet the incidence of damage during resuscitation remains unknown. Objective: We sought to explore the incidence of defibrillator damage employing DSED for RVF during OHCA. Methods: We conducted a survey of EMS agencies, authors of previous publications, EMS medical directors, base hospital medical oversight groups, and defibrillator manufacturers to assess the incidence of defibrillator damage during DSED. Our survey focused on the frequency of DSED use, number of shocks used during DSED, technique used to employ DSED (simultaneous or sequential), and the incidence of defibrillator damage during DSED. We specifically targeted groups that were known to be using DSED in clinical practice. Results: Our survey response rate was 50% (65/129): 61% (34/56) EMS medical directors, 60% (6/10) authors, 100% (8/8) base hospitals, 33% (1/3) defibrillator manufacturers, 31% (16/52) paramedic services. In our case-based analysis the overall incidence of defibrillator damage was 0.4%. The incidence of defibrillator damage based on total number of DSED shocks was estimated between 0.11% and 0.22%. All reported cases of defibrillator damage occurred using a simultaneous defibrillation technique. Conclusion: When DSED is employed using either a sequential or simultaneous technique the rate of defibrillator damage appears to be exceedingly low. Further high-quality evidence is required to determine the impact of DSED on patient centered outcomes, but the incidence of defibrillator damage should not limit it use. Defibrillator damage should continue to be monitored in future trials and clinical practice.

Indexed as

Defibrillator DamageDouble sequential external DefibrillationOut-of-Hospital Cardiac ArrestRefractory Ventricular Fibrillation

Identifiers

PMID36105412
PMCPMC9464949
OpenAlexW4294796387

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.