Evidence map›Paper›PMID 36104356›Full record

ArticleScientific reports2022

Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology.

Carla Alfonso, Miguel A Garcia-Gonzalez, Eva Parrado, Jessyca Gil-Rojas, Juan Ramos-Castro, Lluis Capdevila

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.1field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Carla Alfonso *Laboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona (UAB), 08193, Bellaterra, Barcelona, Spain.
Miguel A Garcia-Gonzalez *Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain.
Eva ParradoLaboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona (UAB), 08193, Bellaterra, Barcelona, Spain.
Jessyca Gil-RojasGroup of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain.
Juan Ramos-CastroGroup of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain.
Lluis CapdevilaLaboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona (UAB), 08193, Bellaterra, Barcelona, Spain. lluis.capdevila@uab.cat.
Universitat Autònoma de Barcelona · ESUniversitat Politècnica de Catalunya · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearables are being increasingly used to monitor heart rate (HR). However, their usefulness for analyzing continuous HR in research or at clinical level is questionable. The aim of this study is to analyze the level of agreement between different wearables in the measurement of HR based on photoplethysmography, according to different body positions and physical activity levels, and compared to a gold-standard ECG. The proposed method measures agreement among several time scales since different wearables obtain HR at different sampling rates. Eighteen university students (10 men, 8 women; 22 ± 2.45 years old) participated in a laboratory study. Participants simultaneously wore an Apple Watch and a Polar Vantage watch. ECG was measured using a BIOPAC system. HR was recorded continuously and simultaneously by the three devices, for consecutive 5-min periods in 4 different situations: lying supine, sitting, standing and walking at 4 km/h on a treadmill. HR estimations were obtained with the maximum precision offered by the software of each device and compared by averaging in several time scales, since the wearables obtained HR at different sampling rates, although results are more detailed for 5 s and 30 s epochs. Bland-Altman (B-A) plots show that there is no noticeable difference between data from the ECG and any of the smartwatches while participants were lying down. In this position, the bias is low when averaging in both 5 s and 30 s. Differently, B-A plots show that there are differences when the situation involves some level of physical activity, especially for shorter epochs. That is, the discrepancy between devices and the ECG was greater when walking on the treadmill and during short time scales. The device showing the biggest discrepancy was the Polar Watch, and the one with the best results was the Apple Watch. We conclude that photoplethysmography-based wearable devices are suitable for monitoring HR averages at regular intervals, especially at rest, but their feasibility is debatable for a continuous analysis of HR for research or clinical purposes, especially when involving some level of physical activity. An important contribution of this work is a new methodology to synchronize and measure the agreement against a gold standard of two or more devices measuring HR at different and not necessarily even paces.

Indexed as

PhotoplethysmographyWearable Electronic DevicesAdultExerciseFemaleHeart RateHumansMaleMonitoring, PhysiologicYoung Adult

Identifiers

PMID36104356
PMCPMC9474518
OpenAlexW4295679172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.