Evidence map›Paper›PMID 36102991›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2022

Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals.

Daniel Fell, Elias Diarbakerli, Paul Gerdhem

Open access · hybridAbstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Observational
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Daniel FellDepartment of Reconstructive Orthopaedics, Karolinska University Hospital, 171 76, Solna, Sweden.ORCID http://orcid.org/0000-0001-5440-3559
Elias DiarbakerliDepartment of Clinical Science Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.ORCID http://orcid.org/0000-0002-4511-4349
Paul GerdhemDepartment of Clinical Science Intervention and Technology, Karolinska Institutet, Stockholm, Sweden. paul.gerdhem@ki.se.ORCID http://orcid.org/0000-0001-8061-7163
Karolinska University Hospital · SEUppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to evaluate the levels of chromium (Cr), cobalt (Co), and titanium (Ti) after instrumented fusion for scoliosis.

methodsSerum samples were collected at median 2.24 (range 0.1-38.8) years after fusion surgery for scoliosis in 91 individuals, of which 71 had been treated with steel implants and 20 with titanium implants. 91 sex and age-matched non-surgically treated individuals with scoliosis were used as controls. Levels of Cr, Co, and Ti were measured.

resultsIn the 91 surgically treated individuals median levels of Cr were 0.54 µg/l vs 0 µg/l in the 91 controls, p < 0.001. Corresponding results for Co were 0.29 µg/l vs. 0.24 µg/l, p = 0.19, and for Ti were 0 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants and their corresponding controls median Cr levels were 0.63 µg/l vs. 0.00 µg/l, p < 0.001 and Co levels 0.27 µg/l vs. 0.23 µg/l, p = 0.36. No Ti was detected. In the individuals with titanium implants, median Cr levels were 0 µg/l vs. 0 µg/l in their corresponding controls, p = 0.38. Corresponding results for Co was 0.39 µg/l vs. 0.31 µg/l, p = 0.27 and for Ti 4.31 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants a negative correlation between implant time in situ and levels of Cr was found ([Formula: see text] = - 0.52, p < 0.001) but not with Co ([Formula: see text] = - 0.14, p = 0.23). Ti was not detected. In the individuals with titanium implants, there was no correlation between implant time in situ and levels of Cr ([Formula: see text] = 0.36, p = 0.12), Co ([Formula: see text] = - 0.12, p = 0.60) or Ti ([Formula: see text] = 0.22, p = 0.35).

conclusionThe use of stainless steel and titanium implants in spinal fusion surgery is associated with elevated metal ion concentrations several years after surgery.

Indexed as

ScoliosisCase-Control StudiesChromiumCobaltHumansMetalsStainless SteelTitaniumChromiumCobaltMetalsStainless SteelTitaniumMetal ionsScoliosisSpinal deformitySpinal fusionSpine surgery

Identifiers

PMID36102991
OpenAlexW4295669654

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.