SynthesisHernia : the journal of hernias and abdominal wall surgery2022
Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis.
Synthesis in Hernia : the journal of hernias and abdominal wall surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 16 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 3 syntheses or guidelines pooled it, 35 citations in OpenAlex.
- Meta-analysis of controlled studies comparing biologic and synthetic unabsorbable mesh in contaminated fields.Surgical endoscopy · 2025Pooled it
- Synthetic vs. biologic mesh for abdominal wall reconstruction in contaminated surgical fields. A meta-analysis of randomized controlled trials and observational studies.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- The use of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh in ventral hernia repair: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- Postoperative complication burden after ventral hernia repair stratified by modified ventral hernia working group grade: a claims-based cohort study.Hernia : the journal of hernias and abdominal wall surgery · 2026Article
- Article
- Prospective cohort study of biological versus and synthetic meshes for laparoscopic repair of hiatal hernia.Hernia : the journal of hernias and abdominal wall surgery · 2025Article
- Mesh removal and ventral hernia repair with long-term absorbable mesh in case of mesh infection.Hernia : the journal of hernias and abdominal wall surgery · 2025Article
- Implant Infectious Diseases: An Introduction to Biomaterials for ID Physicians.Open forum infectious diseases · 2025Review
- Use of Biologic and Biosynthetic Mesh for Ventral Hernia Repair in Current Practice.JAMA surgery · 2025Article
- Simultaneous incisional hernia repair and colorectal surgery: one or two-step procedure?Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- The combination of the three modifications of the component separation technique in the management of complex subcostal abdominal wall hernia. Author's reply.Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- Comment to: Biosynthetic meshes in contaminated fields: where are we now? A systematic review and meta-analysis in humans.Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- Comment to: Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- Adequate Reporting Among Ventral Hernia Repair Operative Reports: A Cross-Sectional Study of Prevalence of Details and Association With Clinical Outcomes.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024Article
- Case Report: Abdominal Wall Abscess as First Clinical Sign of Jejunal Perforation After Blunt Abdominal Trauma.Journal of abdominal wall surgery : JAWS · 2024Article
- Slowly absorbable mesh in sublay ventral hernia repair in contaminated fields.Surgical endoscopy · 2023Article
Corrections and comments
- Commented on by
- Erratum issued
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe use of mesh is a common practice in ventral hernia repair (VHR). Lack of consensus on which prosthetic material works better in different settings remains. This meta-analysis aims to summarize the available evidence on hernia recurrence and complications after repair with synthetic, biologic, or biosynthetic/bioabsorbable meshes in hernias grade 2-3 of the Ventral Hernia Working Group modified classification.
methodsA literature search was conducted in January 2021 using Web of Science (WoS), Scopus, and MEDLINE (via PubMed) databases. Randomized Controlled Trials (RCTs) and observational studies with adult patients undergoing VHR with either synthetic, biologic, or biosynthetic/bioabsorbable mesh were included. Outcomes were hernia recurrence, Surgical Site Occurrence (SSO), Surgical Site Infection (SSI), 30 days re-intervention, and infected mesh removal. Random-effects meta-analyses of pooled proportions were performed. Quality of the studies was assessed, and heterogeneity was explored through sensitivity analyses.
results25 articles were eligible for inclusion. Mean age ranged from 47 to 64 years and participants' follow-up ranged from 1 to 36 months. Biosynthetic/bioabsorbable mesh reported a 9% (95% CI 2-19%) rate of hernia recurrence, lower than synthetic and biologic meshes. Biosynthetic/bioabsorbable mesh repair also showed a lower incidence of SSI, with a 14% (95% CI 6-24%) rate, and there was no evidence of infected mesh removal. Rates of seroma were similar for the different materials.
conclusionsThis meta-analysis did not show meaningful differences among materials. However, the best proportions towards lower recurrence and complication rates after grade 2-3 VHR were after using biosynthetic/slowly absorbable mesh reinforcement. These results should be taken with caution, as head-to-head comparative studies between biosynthetic and synthetic/biologic meshes are lacking. Although, biosynthetic/bioabsorbable materials could be considered an alternative to synthetic and biologic mesh reinforcement in these settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.