ArticleZhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences2022
Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.
Article in Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 3 citations in OpenAlex.
- Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial.Journal of orthopaedic surgery and research · 2025Trial
- Tension-band high-strength suture combined with absorbable screws with cortical penetration for treating Mayo type IIA olecranon fractures: finite element analysis, biomechanical testing, and clinical study.Frontiers in bioengineering and biotechnology · 2026Article
- A short-term efficacy comparison between the FNS and THA as interventions for unstable femoral neck fracture.Frontiers in surgery · 2025Article
- Comparison of the clinical efficacy of three cannulated screws with parallel distribution and inverted triangular distribution in the treatment of femoral neck fractures in the elderly.Experimental and therapeutic medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
objectivesPauwels III fracture is a kind of femoral neck fractures, in which the angle of the fracture line in the coronal plane and the upper edge of the acetabulum is more than 50°. Internal fixation for the treatment of femoral neck fractures is largely performed by cannulated compression screw (CCS), dynamic hip screw, or locking plate. This study aims to compare the biomechanical properties of parallel CCS combined with medial buttress plate fixation and F-type CCS fixation in the treatment of Pauwels III femoral neck fracture by finite element modeling and to determinate the most suitable procedure for such fractures.
methodsA 52-year-old male volunteer, 176 cm in height and 72 kg in weight, with no history of hip joint, was selected. X-ray and CT examination confirmed that the morphology and bone condition of the right hip of the volunteer were normal. A simulation model of Pauwels III femoral neck fracture was established from the collected CT data of the right proximal femur of the volunteer by the finite element method. Four internal fixations were developed to treat the finite element model: Three CCSs in an inverted triangular parallel configuration combined with medial buttress plate model served as Group A, 2 CCSs in a vertical parallel configuration combined with medial buttress plate model served as Group B, 2 CCSs in a horizontal parallel configuration combined with medial buttress model served as Group C, and the "F" shaped CCS model served as Group D. The distribution of stress, the peak stress, the distribution and maximum of displacement of internal fixations and fracture ends in different models were evaluated.
resultsFor Groups A, B, C, and D, the peak stresses on the internal fixation were 362.74, 586.84, 558.25, and 208.66 mPa, respectively, all of which occurred near the fractures and the stress distribution in Group D was the most uniform. The maximum displacements of internal fixations in Groups A, B, C, and D were 0.39, 0.45, 0.44, and 0.41 mm, respectively; the peak stresses on the fracture ends were 70.62, 98.48, 55.84, and 65.39 mPa, respectively, all of which were concentrated on the base of femoral neck and lateral cortex of the femoral shaft, and the stresses of Groups C and D were more evenly distributed than those of Groups A and B. The maximum displacements of fracture ends in Groups A, B, C, and D were 0.44, 0.52, 0.50, and 0.44 mm, respectively.
conclusionsThe biomechanical stability of F-type CCS fixation is similar to that of 3 CCSs in an inverted triangular parallel configuration combined with medial buttress plate, with a better dispersion of stress. F-type CCS fixation may be a well option for the treatment of femoral neck fracture of Pauwels III.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.