ArticleIEEE transactions on radiation and plasma medical sciences2022
The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification.
Article in IEEE transactions on radiation and plasma medical sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring.Zeitschrift fur medizinische Physik · 2023Article
- A feasibility study of enhanced prompt gamma imaging for range verification in proton therapy using deep learning.Physics in medicine and biology · 2023Article
- Applications of Machine Learning to Improve the Clinical Viability of Compton Camera BasedFrontiers in physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The purpose of this study was to determine how the characteristics of the data acquisition (DAQ) electronics of a Compton camera (CC) affect the quality of the recorded prompt gamma (PG) interaction data and the reconstructed images, during clinical proton beam delivery. We used the Monte-Carlo-plus-Detector-Effect (MCDE) model to simulate the delivery of a 150 MeV clinical proton pencil beam to a tissue-equivalent plastic phantom. With the MCDE model we analyzed how the recorded PG interaction data changed as two characteristics of the DAQ electronics of a CC were changed: (1) the number of data readout channels; and (2) the active charge collection, readout, and reset time. As the proton beam dose rate increased, the number of recorded PG single-, double-, and triple-scatter events decreased by a factor of 60× for the current DAQ configuration of the CC. However, as the DAQ readout channels were increased and the readout/reset timing decreased, the number of recorded events decreased by <5× at the highest clinical dose rate. The increased number of readout channels and reduced readout/reset timing also resulted in higher quality recorded data. That is, a higher percentage of the recorded double- and triple-scatters were "true" events (caused by a single incident gamma) and not "false" events (caused by multiple incident gammas). The increase in the number and the quality of recorded data allowed higher quality PG images to be reconstructed even at the highest clinical dose rates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.