Evidence map›Paper›PMID 36090887›Full record

ArticleFrontiers in neurology2022

Frictional force analysis of stent retriever devices using a realistic vascular model: Pilot study.

Youngseok Kwak, Wonsoo Son, Byoung-Joon Kim, Myungsoo Kim, Sang-Youl Yoon, Jaechan Park, Jongkyeong Lim, Joonwon Kim, Dong-Hun Kang

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Youngseok KwakDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Wonsoo SonDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Byoung-Joon KimDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Myungsoo KimDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Sang-Youl YoonDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Jaechan ParkDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Jongkyeong LimDepartment of Mechanical Engineering, Gachon University, Seongnam-si, South Korea.
Joonwon KimDepartment of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea.
Dong-Hun KangDepartment of Neurosurgery, School of Medicine, Kyungpook National University, Daegu, South Korea.
Kyungpook National University · KRGachon University · KRPohang University of Science and Technology · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To date, no vascular model to analyze frictional forces between stent retriever devices and vessel walls has been designed to be similar to the real human vasculature. We developed a novel Methods: A vascular mold was created based on digital subtraction angiography of a patient's cerebral vessels. The vascular model was constructed using polydimethylsiloxane (PDMS, Dow Corning, Inc.) as a silicone elastomer. The vascular model was coated on its inner surface with a lubricating layer to create a low coefficient of friction (~0.037) to closely approximate the intima. A pulsatile blood pump was used to produce blood flow inside the model to approximate real vascular conditions. The frictional forces of Trevo XP, Solitaire 2, and Eric 4 were analyzed for initial and maximal friction retrieval forces using this vascular model. The total pulling energy generated during the 3 cm movement was also obtained. Results: Results for initial retrieval force were as follows: Trevo, 0.09 ± 0.04 N; Solitaire, 0.25 ± 0.07 N; and Eric, 0.33 ± 0.21 N. Results for maximal retrieval force were as follows: Trevo, 0.36 ± 0.07 N; Solitaire, 0.54 ± 0.06 N; and Eric, 0.80 ± 0.13 N. Total pulling energy (N·cm) was 0.40 ± 0.10 in Trevo, 0.65 ± 0.10 in Solitaire, and 0.87 ± 0.14 in Eric, respectively. Conclusions: Using a realistic vascular model, different stent retriever devices were shown to have statistically different frictional forces. Future studies using a realistic vascular model are warranted to assess SRT devices.

Indexed as

acute ischemic strokeEric 4frictional retrieval forceSolitaire 2Trevo XPvascular model

Identifiers

PMID36090887
PMCPMC9449119
OpenAlexW4292879512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.