Evidence map›Paper›PMID 36090821›Full record

ArticleJournal of orthopaedic translation2022

Evaluation of interbody fusion efficacy and biocompatibility of a polyetheretherketone/calcium silicate/porous tantalum cage in a goat model.

Kai Yuan, Kai Zhang, Yiqi Yang, Yixuan Lin, Feng Zhou, Jingtian Mei, Hanjun Li, Jie Wei, Zhifeng Yu, Jie Zhao and 1 more

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic translation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Kai YuanShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Kai ZhangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Yiqi YangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Yixuan LinShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Feng ZhouShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Jingtian MeiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Hanjun LiShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Jie WeiKey Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, China.
Zhifeng YuShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Jie ZhaoShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Tingting TangShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
Shanghai Jiao Tong University · CNEast China University of Science and Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To evaluate the interbody fusion efficacy and biocompatibility of a graft-free cage made of polyetheretherketone/calcium silicate composite/porous tantalum (PEEK/CS/pTa cage) compared with a PEEK/CS cage with an autogenous bone graft in a goat model. Methods: PEEK/CS/pTa and PEEK/CS cages were prepared through an injection-moulding method. The PEEK/CS composites and porous tantalum were characterized by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive spectroscopy (EDS) mapping. Then, adult goats were chosen for C2/C3 and C3/C4 discectomy via the anterior cervical approach and randomly implanted with PEEK/CS/pTa and PEEK/CS/cages with autogenous bone grafts. The fusion performance and osseointegration of the cages were evaluated by X-ray imaging, magnetic resonance imaging (MRI) scanning, and bone histomorphometry analysis. Moreover, the concentrations of Ca and Si in urine, serum, tissue around the fusion segments and major organs of the goats were determined by inductively coupled plasma-optical emission spectrometry (ICP-OES). Histological observation of major organs of the goats was used to evaluate the biosafety of PEEK/CS/pTa and PEEK/CS cages. Results: X-ray and MRI imaging suggested that both PEEK/CS/pTa cages and PEEK/CS cages maintained similar average intervertebral space heights. The tissue volumes in the fusion area were comparable between the two groups of cages at 26 weeks after surgery. Histological morphometric data showed that PEEK/CS/pTa cages and PEEK/CS cages with autogenous bone grafts had similar bone contact and osseointegration at 12 and 26 weeks. Element determination of serum, urine, spinal cord, dura matter, bone and organs showed that the CS/PEEK cages did not cause abnormal systemic metabolism or accumulation of calcium and silicon in local tissues and major organs of goats after implantation. No obvious pathological changes were found in the heart, liver, spleen, liver or kidney tissues. Conclusion: Overall, these results suggested that the graft-free PEEK/CS/pTa cage showed similar bony fusion performance to the PEEK/CS cages with autogenous bone grafts. The cages releasing calcium and silicon had good biological safety in vivo.The translational potential of this article: This study provided a new graft-free interbody fusion solution to patients with degenerative disc diseases, which could avert potential donor-site complications. This study also provided a detailed assessment of element excretion and accumulation of Ca and Si in vivo, which validated the biosafety of this new type of bioactive interbody fusion cage.

Indexed as

BiocompatibilityCalcium silicateInterbody fusion cagePEEKPorous tantalumSpine surgery

Identifiers

PMID36090821
PMCPMC9437743
OpenAlexW4293744568

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.