ArticleProceedings of SPIE--the International Society for Optical Engineering2021

Fluoroscopic Guidance of a Surgical Robot: Pre-clinical Evaluation in Pelvic Guidewire Placement.

R C Vijayan, R Han, P Wu, N M Sheth, P Vagdargi, S Vogt, G Kleinszig, G M Osgood, J H Siewerdsen, A Uneri

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

R C VijayanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
R HanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
P WuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
N M ShethDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
P VagdargiDepartment of Computer Science, Johns Hopkins University, Baltimore MD USA.
S VogtSiemens Healthineers, Erlangen Germany.
G KleinszigSiemens Healthineers, Erlangen Germany.
G M OsgoodDepartment of Orthopaedic Surgery, Johns Hopkins University, Baltimore MD USA.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
A UneriDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD USA.
Johns Hopkins University · USSiemens Healthcare (Germany) · DE

Funding

BIOMEDICAL ENGINEERING TRAINING PROGRAMT32GM007057 · NIGMS · JOHNS HOPKINS UNIVERSITY · PI KANOLD, PATRICK O, KARCHIN, RACHEL · 1985 to 2023
$10.4M
Intraoperative Imaging for Guidance, Patient Safety, and OR Quality AssuranceR01EB017226 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SIEWERDSEN, JEFFREY H · 2014 to 2017
$2.1M
NIBIB NIH HHS R01 EB017226NIGMS NIH HHS T32 GM007057
6 · The paper itself

Abstract

Purpose: A method and prototype for a fluoroscopically-guided surgical robot is reported for assisting pelvic fracture fixation. The approach extends the compatibility of existing guidance methods with C-arms that are in mainstream use (without prior geometric calibration) using an online calibration of the C-arm geometry automated via registration to patient anatomy. We report the first preclinical studies of this method in cadaver for evaluation of geometric accuracy. Methods: The robot is placed over the patient within the imaging field-of-view and radiographs are acquired as the robot rotates an attached instrument. The radiographs are then used to perform an online geometric calibration via 3D-2D image registration, which solves for the intrinsic and extrinsic parameters of the C-arm imaging system with respect to the patient. The solved projective geometry is then be used to register the robot to the patient and drive the robot to planned trajectories. This method is applied to a robotic system consisting of a drill guide instrument for guidewire placement and evaluated in experiments using a cadaver specimen. Results: Robotic drill guide alignment to trajectories defined in the cadaver pelvis were accurate within 2 mm and 1° (on average) using the calibration-free approach. Conformance of trajectories within bone corridors was confirmed in cadaver by extrapolating the aligned drill guide trajectory into the cadaver pelvis. Conclusion: This study demonstrates the accuracy of image-guided robotic positioning without prior calibration of the C-arm gantry, facilitating the use of surgical robots with simpler imaging devices that cannot establish or maintain an offline calibration. Future work includes testing of the system in a clinical setting with trained orthopaedic surgeons and residents.

Indexed as

3D-2D registrationC-arm imaginggeometric calibrationImage-guided surgerysurgical robotics

Identifiers

PMID36090307
PMCPMC9455933
OpenAlexW3129837159

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.