Evidence map›Paper›PMID 36089983›Full record

ArticleGeoHealth2022

Barking up the Right Tree: Using Tree Bark to Track Airborne Particles in School Environment and Link Science to Society.

A D S Leite, S Rousse, J-F Léon, R I F Trindade, S Haoues-Jouve, C Carvallo, M Dias-Alves, A Proietti, E Nardin, M Macouin

Open access · goldAbstract read
In one paragraph

Article in GeoHealth, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

A D S LeiteGéosciences Environnement Toulouse CNRS IRD Université Toulouse 3 CNES Toulouse France.ORCID https://orcid.org/0000-0003-0723-7804
S RousseGéosciences Environnement Toulouse CNRS IRD Université Toulouse 3 CNES Toulouse France.
J-F LéonLaboratoire d'Aérologie CNRS Université Toulouse 3 Toulouse France.ORCID https://orcid.org/0000-0002-1251-0361
R I F TrindadeDepartamento de Geofísica Instituto de Astronomia, Geofísica e Ciências Atmosféricas Universidade de São Paulo São Paulo Brazil.ORCID https://orcid.org/0000-0001-9848-9550
S Haoues-JouveLaboratoire Interdisciplinaire Solidarités Sociétés Territoires CNRS Université Toulouse 2 EHESS ENSFEA Toulouse France.
C CarvalloInstitut de Minéralogie, de Physique des Matériaux et de Cosmochimie UMR 7590 Sorbonne Université Paris France.
M Dias-AlvesLaboratoire d'Aérologie CNRS Université Toulouse 3 Toulouse France.
A ProiettiCentre de Microcaractérisation Raimond Castaing Université Toulouse 3 Toulouse France.
E NardinGéosciences Environnement Toulouse CNRS IRD Université Toulouse 3 CNES Toulouse France.
M MacouinGéosciences Environnement Toulouse CNRS IRD Université Toulouse 3 CNES Toulouse France.ORCID https://orcid.org/0000-0002-0421-4730
Centre National de la Recherche Scientifique · FRSorbonne Université · FRUniversidade de São Paulo · BRUniversité Fédérale de Toulouse Midi-Pyrénées · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Children's exposure to air pollution affects both their health and learning skills. Fine and ultrafine particulate matter (PM2.5, PM1), notably issued from traffic sources in urban centers, belong to the most potential harmful health hazards. However their monitoring and the society's awareness on their dangers need to be consolidated. In this study, raising teacher and pupil involvement for air quality improvement in their schools environment is reached through developing a passive monitoring technique (bio-sensors made of tree bark). The experiment was implemented in two urban elementary schools situated close to a main traffic road of the city of Toulouse (South of France). Magnetic properties, carbonaceous fraction measurements, and scanning electronic microscopy (SEM-EDX) investigations were realized both on passive bio-sensors and filters issued from active sampling. We find that traffic is the main PM1 source for both outdoors and indoors at schools. Higher levels of outdoor PM in the school's environments compared to urban background are reached especially in the cold period. The schools proximity to a main traffic source and lack of ventilation are the main causes for observed PM1 accumulation in classrooms. The co-working experiment with educational teams and pupils shows that the use of bio-sensors is a driver for children empowerment to air pollution and therefore represents a potential key tool for the teachers though limiting eco-anxiety. As PM accumulation is observed in many scholar environments across Europe, the proposed methodology is a step toward a better assessment of PM impact on pupil's health and learning skills.

Indexed as

air qualitycarbonaceous speciescitizen scienceenvironmental magnetismparticulate matterschool environment

Identifiers

PMID36089983
PMCPMC9432803
OpenAlexW4292692792

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.