Evidence map›Paper›PMID 36088303›Full record

ArticleBMC anesthesiology2022

Comparing suction rates of novel DuCanto catheter against Yankauer and standard suction catheter using liquids of different viscosity-a technical simulation.

Simon-Richard Finke, Daniel C Schroeder, Hannes Ecker, Bernd W Böttiger, Holger Herff, Wolfgang A Wetsch

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC anesthesiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Acute lethargy, stridor, and hypoxemia in a young adult.Journal of the American College of Emergency Physicians open · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Simon-Richard FinkeDepartment of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Daniel C SchroederDepartment of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Hannes EckerDepartment of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Bernd W BöttigerDepartment of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Holger HerffDepartment of Anesthesiology, PAN Clinic, Cologne, Germany.
Wolfgang A WetschDepartment of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany. wolfgang.wetsch@uk-koeln.de.
University of Cologne · DEBundeswehrzentralkrankenhaus Koblenz · DEUniversity Hospital Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAspiration is a feared complication that may occur during airway management, and can significantly contribute to morbidity and mortality. Availability of a suctioning device with a suction catheter capable of clearing the airway is mandatory for airway management. However, suction performance may be significantly different amongst different suction catheters. The aim of this study was to compare suction rates of a standard 14 Ch suction catheter (SC), a Yankauer catheter (Y) and a DuCanto catheter (DC) using 4 fluids with different viscosity.

methodsIn this simulation trial, 4 preparations with standardized viscosity were prepared using a Xanthane-based medical fluid thickener. Lowest viscosity was achieved using tap water without thickener, syrup-like viscosity was achieved by adding 10 g per liter tap water, honey-like viscosity was achieved by adding 20 g per liter, and a pudding-like viscosity was achieved by adding 30 g of thickening powder per liter tap water. Each preparation was suctioned for 15 s with the three different suctioning devices. Measurements were repeated four times. The amount of removed preparation by suctioning was measured using a tared scale.

resultsSuction rates for water were 580 ± 34 mg for SC, 888 ± 5 mg for Y and 1087 ± 15 for DC; for syrup-like viscosity it was 383 ± 34(SC) vs. 661 ± 64(Y) vs. 935 ± 42(DC); for honey-like viscosity it was 191 ± 21(SC) vs. 426 ± 34(Y) vs. 590 ± 68(DC); and for pudding-like viscosity 74 ± 13(SC) vs. 164 ± 6(Y) vs. 211 ± 8(DC).

conclusionSuctioning liquids of different viscosity, the new DuCanto catheter was more effective than the Yankauer catheter that was more effective than a standard suctioning catheter. The relative superiority of the DuCanto was highest in fluids with high viscosity.

Indexed as

CatheterizationCathetersSuctionViscosityWaterWaterAirwayAspirationDuCantoMendelson syndromeRegurgitationSuctioning catheterYankauer catheter

Identifiers

PMID36088303
PMCPMC9463842
OpenAlexW4295095286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked