Evidence map›Paper›PMID 36087229›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Electromagnetic tool for the endoscopic creation of colon anastomoses-development and feasibility assessment of a novel anastomosis compression implant approach.

Jana Steger, Anne Zimmermann, Thomas Wittenberg, Petra Mela, Dirk Wilhelm

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jana StegerResearch Group Minimally-Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts Der Isar, Technical University of Munich, Trogerstraße 26, 81675, Munich, Germany. jana.steger@tum.de.ORCID http://orcid.org/0000-0002-5576-3262
Anne ZimmermannResearch Group Minimally-Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts Der Isar, Technical University of Munich, Trogerstraße 26, 81675, Munich, Germany.
Thomas WittenbergDepartment of Computer Science, Institute of Visual Computing, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany.
Petra MelaDepartment of Mechanical Engineering and Munich Institute of Biomedical Engineering, Chair of Medical Materials and Implants, TUM School of Engineering and Design, Technical University of Munich, Garching, Germany.
Dirk WilhelmResearch Group Minimally-Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts Der Isar, Technical University of Munich, Trogerstraße 26, 81675, Munich, Germany.
TUM Klinikum · DETechnical University of Munich · DE

Funding

Deutsche Forschungsgemeinschaft 386233407
6 · The paper itself

Abstract

backgroundColorectal anastomoses are among the most commonly performed interventions in abdominal surgery, while associated patient trauma is still high. Most recent trends of endoscopic anastomosis devices integrate magnetic components to overcome the challenges of minimally invasive surgery. However, the mutual attraction between magnetic implant halves may increase the risk of inadvertently pinching healthy structures. Thus, we present a novel anastomosis device to improve system controllability and flexibility.

methodsA magnetic implant and an applicator with electromagnetic control units were developed. The interaction of magnetic implants with the electromagnets bears particular challenges with respect to the force-related dimensioning. Here, attraction forces must be overcome by the electromagnet actuation to detach the implant, while the attraction force between the implant halves must be sufficient to ensure a stable connection. Thus, respective forces were measured and the detachment process was reproducibly investigated. Patient hazards, associated with resistance-related heating of the coils were investigated.

resultsAnastomosis formation was reproducibly successful for an implant, with an attraction force of 1.53 [Formula: see text], resulting in a compression pressure of [Formula: see text]. The implant was reproducibly detachable from the applicator at the anastomosis site. Coils heated up to a maximum temperature of [Formula: see text]. Furthermore, we were able to establish a neat reconnection of intestinal bowel endings using our implant. DISCUSSION: As we achieved nearly equal compression forces with our implant as other magnetic anastomosis systems did (Magnamosis™: 1.48 N), we concluded that our approach provides sufficient holding strength to counteract the forces acting immediately postoperatively, which would eventually lead to an undesired slipping of the implant halves during the healing phase. Based on heat transfer investigations, preventive design specifications were derived, revealing that the wall thickness of a polymeric isolation is determined rather by stability considerations, than by heat shielding requirements.

Indexed as

Electromagnetic PhenomenaRectumAnastomosis, SurgicalColonFeasibility StudiesHumansAnastomosisElectromagnetEndoscopicImplantSurgery