ArticleAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2022

The Position and Orientation of the Pulse Generator Affects MRI RF Heating of Epicardial Leads in Children.

Bhumi Bhusal, Fuchang Jiang, Daniel Kim, KyungPyo Hong, Michael C Monge, Gregory Webster, Giorgio Bonmassar, Laleh Golestanirad

Open access · bronzeAbstract read
In one paragraph

Article in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.8field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. RF-induced heating of capped and uncapped abandoned epicardial leads during MRI at 1.5 T and 3 T.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023
    Article
  4. Rapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Bhumi Bhusal
Fuchang Jiang
Daniel Kim
KyungPyo Hong
Michael C Monge
Gregory Webster
Giorgio Bonmassar
Laleh Golestanirad
Northwestern University · USAthinoula A. Martinos Center for Biomedical Imaging · US

Funding

Reconfigurable MRI technology for safe and high-resolution imaging of deep brain stimulation at 3TR01EB030324 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2021 to 2024
$2.1M
NIBIB NIH HHS R01 EB030324
6 · The paper itself

Abstract

Infants and children with congenital heart defects often receive a cardiac implantable electronic device (CIED). Because transvenous access to the heart is difficult in patients with small veins, the majority of young children receive epicardial CIEDs. Unfortunately, however, once an epicardial CIED is placed, patients are no longer eligible to receive magnetic resonance imaging (MRI) exams due to the unknown risk of MRI-induced radiofrequency (RF) heating of the device. Although many studies have assessed the role of device configuration in RF heating of endocardial CIEDs in adults, such case for epicardial devices in pediatric patients is relatively unexplored. In this study, we evaluated the variation in RF heating of an epicardial lead due to changes in the lateral position and orientation of the implantable pulse generator (IPG). We found that changing the orientation and position of the IPG resulted in a five-fold variation in the RF heating at the lead's tip. Maximum heating was observed when the IPG was moved to a left lateral abdominal position of patient, and minimum heating was observed when the IPG was positioned directly under the heart. Clinical Relevance- This study examines the role of device configuration on MRI-induced RF heating of an epicardial CIED in a pediatric phantom. Results could help pediatric cardiac surgeons to modify device implantation to reduce future risks of MRI in patients.

Indexed as

HeatingRadio WavesAdultChildChild, PreschoolHumansMagnetic Resonance ImagingPhantoms, ImagingProstheses and Implants