Evidence map›Paper›PMID 36082481›Full record

ArticleJournal of biomechanical engineering2023

Optimizing the Porohyperelastic Response of a Layered Compliance Matched Vascular Graft to Promote Luminal Self-Cleaning.

Ali Behrangzade, Bruce R Simon, William R Wagner, Jonathan P Vande Geest

Abstract read
In one paragraph

Article in Journal of biomechanical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ali BehrangzadeDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219.
Bruce R SimonAerospace and Mechanical Engineering, Biomedical Engineering Interdisciplinary Program University of Arizona, Tucson, AZ 85721.
William R WagnerDepartment of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219; Department of Bioengineering, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219.
Jonathan P Vande GeestDepartment of Bioengineering, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute, University of Pittsburgh, Pittsburgh, PA 15219; Department of Mechanical Engineering and Material Science, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute University of Pittsburgh, Pittsburgh, PA 15219.

Funding

Preclinical Assessment of a Compliance Matched Biopolymer Vascular Graft - Diversity SupplementR01HL157017 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI VANDE GEEST, JONATHAN PIETER · 2022 to 2025
$3.1M
American Heart Association 20PRE35211036NHLBI NIH HHS R01 HL157017
6 · The paper itself

Abstract

Thrombosis and intimal hyperplasia have remained the major failure mechanisms of small-diameter vascular grafts used in bypass procedures. While most efforts to reduce thrombogenicity have used a biochemical surface modification approach, the use of local mechanical phenomena to aid in this goal has received somewhat less attention. In this work, the mechanical, fluid transport, and geometrical properties of a layered and porous vascular graft are optimized within a porohyperelastic finite element framework to maximize self-cleaning via luminal reversal fluid velocity (into the lumen). This is expected to repel platelets as well as inhibit the formation of and/or destabilize adsorbed protein layers thereby reducing thrombogenic potential. A particle swarm optimization algorithm was utilized to maximize luminal reversal fluid velocity while also compliance matching our graft to a target artery (rat aorta). The maximum achievable luminal reversal fluid velocity was approximately 246 μm/s without simultaneously optimizing for host compliance. Simultaneous optimization of reversal flow and compliance resulted in a luminal reversal fluid velocity of 59 μm/s. Results indicate that a thick highly permeable compressible inner layer and a thin low permeability incompressible outer layer promote intraluminal reversal fluid velocity. Future research is needed to determine the feasibility of fabricating such a layered and optimized graft and verify its ability to improve hemocompatibility.

Indexed as

Models, CardiovascularVascular GraftingAnimalsArteriesBlood Vessel ProsthesisComplianceRats

Identifiers

PMID36082481
PMCPMC9632477

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.