Evidence map›Paper›PMID 36081868›Full record

ArticleFrontiers in neurology2022

Expert validation of prediction models for a clinical decision-support system in audiology.

Mareike Buhl, Gülce Akin, Samira Saak, Ulrich Eysholdt, Andreas Radeloff, Birger Kollmeier, Andrea Hildebrandt

Abstract read
In one paragraph

Article in Frontiers in neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mareike BuhlDepartment of Medical Physics and Acoustics, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Gülce AkinCluster of Excellence Hearing4all, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Samira SaakDepartment of Medical Physics and Acoustics, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Ulrich EysholdtDepartment of Medical Physics and Acoustics, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Andreas RadeloffCluster of Excellence Hearing4all, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Birger KollmeierDepartment of Medical Physics and Acoustics, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
Andrea HildebrandtCluster of Excellence Hearing4all, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For supporting clinical decision-making in audiology, Common Audiological Functional Parameters (CAFPAs) were suggested as an interpretable intermediate representation of audiological information taken from various diagnostic sources within a clinical decision-support system (CDSS). Ten different CAFPAs were proposed to represent specific functional aspects of the human auditory system, namely hearing threshold, supra-threshold deficits, binaural hearing, neural processing, cognitive abilities, and a socio-economic component. CAFPAs were established as a viable basis for deriving audiological findings and treatment recommendations, and it has been demonstrated that model-predicted CAFPAs, with machine learning models trained on expert-labeled patient cases, are sufficiently accurate to be included in a CDSS, but it requires further validation by experts. The present study aimed to validate model-predicted CAFPAs based on previously unlabeled cases from the same data set. Here, we ask to which extent domain experts agree with the model-predicted CAFPAs and whether potential disagreement can be understood in terms of patient characteristics. To these aims, an expert survey was designed and applied to two highly-experienced audiology specialists. They were asked to evaluate model-predicted CAFPAs and estimate audiological findings of the given audiological information about the patients that they were presented with simultaneously. The results revealed strong relative agreement between the two experts and importantly between experts and the prediction for all CAFPAs, except for the neural processing and binaural hearing-related ones. It turned out, however, that experts tend to score CAFPAs in a larger value range, but, on average, across patients with smaller scores as compared with the machine learning models. For the hearing threshold-associated CAFPA in frequencies smaller than 0.75 kHz and the cognitive CAFPA, not only the relative agreement but also the absolute agreement between machine and experts was very high. For those CAFPAs with an average difference between the model- and expert-estimated values, patient characteristics were predictive of the disagreement. The findings are discussed in terms of how they can help toward further improvement of model-predicted CAFPAs to be incorporated in a CDSS for audiology.

Indexed as

audiological diagnosticsCAFPAsCDSSexpert knowledgeexpert validationmachine learningprecision audiology

Identifiers

PMID36081868
PMCPMC9446152

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.