Evidence map›Paper›PMID 36081347›Full record

ArticleBiophysical journal2022

Geometric effects in gas vesicle buckling under ultrasound.

Hossein Salahshoor, Yuxing Yao, Przemysław Dutka, Nivin N Nyström, Zhiyang Jin, Ellen Min, Dina Malounda, Grant J Jensen, Michael Ortiz, Mikhail G Shapiro

Abstract read
In one paragraph

Article in Biophysical journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Protein Gas Vesicles ofACS nano · 2024
    Article
  8. Truly Tiny Acoustic Biomolecules for Ultrasound Imaging and Therapy.Advanced materials (Deerfield Beach, Fla.) · 2024
    Article
  9. Truly tiny acoustic biomolecules for ultrasound imaging and therapy.bioRxiv : the preprint server for biology · 2023
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hossein SalahshoorDivision of Engineering and Applied Science, California Institute of Technology, Pasadena, California.
Yuxing YaoDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California.
Przemysław DutkaDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California; Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, California.
Nivin N NyströmDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California.
Zhiyang JinDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California.
Ellen MinDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California.
Dina MaloundaDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California.
Grant J JensenDivision of Biology and Biological Engineering, California Institute of Technology, Pasadena, California; College of Physical and Mathematical Sciences, Brigham Young University, Provo, Utah.
Michael OrtizDivision of Engineering and Applied Science, California Institute of Technology, Pasadena, California.
Mikhail G ShapiroDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California; Howard Hughes Medical Institute, Pasadena, California. Electronic address: mikhail@caltech.edu.

Funding

Biogenic Gas Nanostructures As Molecular Imaging Reporters For UltrasoundR01EB018975 · NIBIB · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI Mikhail Shapiro · 2014 to 2026
$5.9M
NIBIB NIH HHS R01 EB018975
6 · The paper itself

Abstract

Acoustic reporter genes based on gas vesicles (GVs) have enabled the use of ultrasound to noninvasively visualize cellular function in vivo. The specific detection of GV signals relative to background acoustic scattering in tissues is facilitated by nonlinear ultrasound imaging techniques taking advantage of the sonomechanical buckling of GVs. However, the effect of geometry on the buckling behavior of GVs under exposure to ultrasound has not been studied. To understand such geometric effects, we developed computational models of GVs of various lengths and diameters and used finite element simulations to predict their threshold buckling pressures and postbuckling deformations. We demonstrated that the GV diameter has an inverse cubic relation to the threshold buckling pressure, whereas length has no substantial effect. To complement these simulations, we experimentally probed the effect of geometry on the mechanical properties of GVs and the corresponding nonlinear ultrasound signals. The results of these experiments corroborate our computational predictions. This study provides fundamental insights into how geometry affects the sonomechanical properties of GVs, which, in turn, can inform further engineering of these nanostructures for high-contrast, nonlinear ultrasound imaging.

Indexed as

AcousticsNanostructuresUltrasonography

Identifiers

PMID36081347
PMCPMC9674984

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.