Evidence map›Paper›PMID 36081149›Full record

ArticleSensors (Basel, Switzerland)2022

Electrodeless Heart and Respiratory Rate Estimation during Sleep Using a Single Fabric Band and Event-Based Edge Processing.

Titus Jayarathna, Gaetano D Gargiulo, Gough Y Lui, Paul P Breen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Artificial Intelligence-Driven Soft Bioelectronics for Self-Powered Respiration Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Titus JayarathnaThe MARCS Institute, Western Sydney University, Westmead, NSW 2145, Australia.ORCID 0000-0002-1849-4235
Gaetano D GargiuloThe MARCS Institute, Western Sydney University, Westmead, NSW 2145, Australia.ORCID 0000-0002-2616-2804
Gough Y LuiThe MARCS Institute, Western Sydney University, Westmead, NSW 2145, Australia.ORCID 0000-0003-1042-5793
Paul P BreenThe MARCS Institute, Western Sydney University, Westmead, NSW 2145, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart rate (HR) and respiratory rate (RR) are two vital parameters of the body medically used for diagnosing short/long-term illness. Out-of-the-body, non-skin-contact HR/RR measurement remains a challenge due to imprecise readings. "Invisible" wearables integrated into day-to-day garments have the potential to produce precise readings with a comfortable user experience. Sleep studies and patient monitoring benefit from "Invisibles" due to longer wearability without significant discomfort. This paper suggests a novel method to reduce the footprint of sleep monitoring devices. We use a single silver-coated nylon fabric band integrated into a substrate of a standard cotton/nylon garment as a resistive elastomer sensor to measure air and blood volume change across the chest. We introduce a novel event-based architecture to process data at the edge device and describe two algorithms to calculate real-time HR/RR on ARM Cortex-M3 and Cortex-M4F microcontrollers. RR estimations show a sensitivity of 99.03% and a precision of 99.03% for identifying individual respiratory peaks. The two algorithms used for HR calculation show a mean absolute error of 0.81 ± 0.97 and 0.86±0.61 beats/min compared with a gold standard ECG-based HR. The event-based algorithm converts the respiratory/pulse waveform into instantaneous events, therefore reducing the data size by 40-140 times and requiring 33% less power to process and transfer data. Furthermore, we show that events hold enough information to reconstruct the original waveform, retaining pulse and respiratory activity. We suggest fabric sensors and event-based algorithms would drastically reduce the device footprint and increase the performance for HR/RR estimations during sleep studies, providing a better user experience.

Indexed as

NylonsRespiratory RateHeart RateHumansPolysomnographySleepNylonsedge computingtextile sensorswearable sensorswireless sensors