Evidence map›Paper›PMID 36080957›Full record

ArticleSensors (Basel, Switzerland)2022

Three-Dimensional Quantitative Evaluation of the Scapular Skin Marker Movements in the Upright Posture.

Yuki Yoshida, Noboru Matsumura, Yoshitake Yamada, Minoru Yamada, Yoichi Yokoyama, Azusa Miyamoto, Masaya Nakamura, Takeo Nagura, Masahiro Jinzaki

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Glenosphere Tilt and Size Predict Shoulder Kinematics During the Hand-to-Back Motion After Reverse Shoulder Arthroplasty.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yuki YoshidaDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0000-0002-0185-7554
Noboru MatsumuraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Yoshitake YamadaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Minoru YamadaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Yoichi YokoyamaDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Azusa MiyamotoDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Masaya NakamuraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.ORCID 0000-0002-2279-7028
Takeo NaguraDepartment of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
Masahiro JinzakiDepartment of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.

Funding

Canon Medical Systems No NumberJapan Society for the Promotion of Science 17H04266Japan Society for the Promotion of Science 20K08056Uehara Memorial Foundation No Number
6 · The paper itself

Abstract

Motion capture systems using skin markers are widely used to evaluate scapular kinematics. However, soft-tissue artifact (STA) is a major limitation, and there is insufficient knowledge of the marker movements from the original locations. This study explores a scapular STA, including marker movements with shoulder elevation using upright computed tomography (CT). Ten healthy males (twenty shoulders in total) had markers attached to scapular bony landmarks and underwent upright CT in the reference and elevated positions. Marker movements were calculated and compared between markers. The bone-based and marker-based scapulothoracic rotation angles were also compared in both positions. The median marker movement distances were 30.4 mm for the acromial angle, 53.1 mm for the root of the scapular spine, and 70.0 mm for the inferior angle. Marker movements were significantly smaller on the superolateral aspect of the scapula, and superior movement was largest in the directional movement. Scapulothoracic rotation angles were significantly smaller in the marker-based rotation angles than in the bone-based rotation angles of the elevated position. We noted that the markers especially did not track the inferior movement of the scapular motion with shoulder elevation, resulting in an underestimation of the marker-based rotation angles.

Indexed as

MovementScapulaBiomechanical PhenomenaHumansMaleRange of Motion, ArticularRotationShoulderStanding Positionmarker displacementoptical motion capture systemsshouldersoft tissue artifactupright computed tomography

Identifiers

PMID36080957
PMCPMC9460682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.