Evidence map›Paper›PMID 36080473›Full record

ArticleMolecules (Basel, Switzerland)2022

Fast and Sensitive HPLC-ESI-MS/MS Method for Etoricoxib Quantification in Human Plasma and Application to Bioequivalence Study.

Gabriel Onn Kit Loh, Emily Yii Ling Wong, Yvonne Tze Fung Tan, Siew Chyee Heng, Mardiana Saaid, Kit Yee Cheah, Nurul Diyana Mohd Sali, Nair Damenthi, Sharon Shi Min Ng, Long Chiau Ming and 1 more

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 2 countries.

Gabriel Onn Kit LohBioxis Sdn. Bhd. PMT 1241, Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, Simpang Ampat 14100, Malaysia.ORCID 0000-0001-5374-9996
Emily Yii Ling WongBioxis Sdn. Bhd. PMT 1241, Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, Simpang Ampat 14100, Malaysia.
Yvonne Tze Fung TanBioxis Sdn. Bhd. PMT 1241, Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, Simpang Ampat 14100, Malaysia.
Siew Chyee HengSchool of Chemical Sciences, Universiti Sains Malaysia, Minden 11800, Malaysia.ORCID 0000-0002-8913-4480
Mardiana SaaidSchool of Chemical Sciences, Universiti Sains Malaysia, Minden 11800, Malaysia.
Kit Yee CheahCentre for Clinical Trial, Institute for Clinical Research, National Institutes of Health, Ministry of Health Malaysia, Hospital Ampang, Ampang 68000, Malaysia.ORCID 0000-0001-6397-5735
Nurul Diyana Mohd SaliCentre for Clinical Trial, Institute for Clinical Research, National Institutes of Health, Ministry of Health Malaysia, Hospital Ampang, Ampang 68000, Malaysia.
Nair DamenthiCentre for Clinical Trial, Institute for Clinical Research, National Institutes of Health, Ministry of Health Malaysia, Hospital Ampang, Ampang 68000, Malaysia.
Sharon Shi Min NgCentre for Clinical Trial, Institute for Clinical Research, National Institutes of Health, Ministry of Health Malaysia, Hospital Ampang, Ampang 68000, Malaysia.
Long Chiau MingPAP Rashidah Sa'adatul Bolkiah Institute of Health Sciences, Universiti Brunei Darussalam, Gadong BE 1410, Brunei.ORCID 0000-0002-6971-1383
Kok Khiang PehSchool of Pharmaceutical Sciences, Universiti Sains Malaysia, Minden 11800, Malaysia.
Ministry of Health · MYUniversiti Sains Malaysia · MYUniversiti Brunei Darussalam · BN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Etoricoxib is a non-steroidal anti-inflammatory drug (NSAID) used to treat pain and inflammation. The objective of the current study was to develop a sensitive, fast and high-throughput HPLC-ESI-MS/MS method to measure etoricoxib levels in human plasma using a one-step methanol protein precipitation technique. A tandem mass spectrometer equipped with an electrospray ionization (ESI) source operated in a positive mode and multiple reaction monitoring (MRM) were used for data collection. The quantitative MRM transition ions were m/z 359.15 > 279.10 and m/z 363.10 > 282.10 for etoricoxib and IS. The linear range was from 10.00 to 4000.39 ng/mL and the validation parameters were within the acceptance limits of the European Medicine Agency (EMA) and Food and Drug Analysis (FDA) guidelines. The present method was sensitive (10.00 ng/mL with S/N > 40), simple, selective (K prime > 2), and fast (short run time of 2 min), with negligible matrix effect and consistent recovery, suitable for high throughput analysis. The method was used to quantitate etoricoxib plasma concentrations in a bioequivalence study of two 120 mg etoricoxib formulations. Incurred sample reanalysis results further supported that the method was robust and reproducible.

Indexed as

Spectrometry, Mass, Electrospray IonizationTandem Mass SpectrometryChromatography, High Pressure LiquidEtoricoxibHumansReproducibility of ResultsTherapeutic EquivalencyEtoricoxibbioequivalence studyetoricoxibetoricoxib D4high-sample throughputhuman plasmaprotein precipitation

Identifiers

PMID36080473
PMCPMC9457878
OpenAlexW4295078727

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked