ArticleMaterials (Basel, Switzerland)2022
Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant-Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study.
Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Rehabilitation in Cases of Maxillary Lateral Incisor Agenesis Using Zirconia Implant and Abutment: Finite Element Analysis and Systematic Review.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026Pooled it
- Evaluation of Internal and External Hexagon Connections in Immediately Loaded Full-Arch Rehabilitations: A Multicenter Randomized Split-Mouth Controlled Trial With a 6-Year Follow-Up.Clinical implant dentistry and related research · 2025Trial
- Article
- Article
- Influence of different customized abutment materials on stress distribution of different internal implant-abutment connections: finite element analysis.BMC oral health · 2025Article
- Biomechanical Analysis of Stress Distribution and Force Dynamics in Nobel Active Implants at Varying Angulations: A Finite Element Study.Acta stomatologica Croatica · 2025Article
- Three-Dimensional Finite Element Analysis of Stress Distribution in Dental Implant Prosthesis and Surrounding Bone Using PEEK Abutments.Biomimetics (Basel, Switzerland) · 2024Article
- Bone Regeneration and Polyetheretherketone Implants in Maxillo-Facial Surgery and Neurosurgery: A Multidisciplinary Study.Biology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Peri-implantitis is a common implant-supported prosthesis complication, and marginal bone loss affects the stress distribution in implant systems. This three-dimensional finite element analysis study investigated how bone loss affects the implant assembly; in particular, models including two implant systems with different connection systems (external or internal hexagon), abutment materials (titanium or zirconia), and bone loss levels (0, 1.5, 3, or 5 mm) were created. We observed that the maximum von Mises stress distinctly increased in the groups with bone loss over 1.5 mm compared to the group without bone loss, regardless of the connection system or abutment material used. Moreover, the screw stress patterns with bone loss progression were determined more by the connection systems than by the abutment materials, and the magnitude of the stress on the fixture was affected by the connection systems with a similar pattern. The highest stress on the screw with the external hexagon connection system increased over 25% when bone loss increased from 3 to 5 mm, exceeding the yield strength of the titanium alloy (Ti-6Al-4V) when 5 mm bone loss exists; clinically, this situation may result in screw loosening or fracture. The highest stress on the fixture, exceeding the yield strength of pure titanium, was noted with the internal hexagon connection system and 1.5 mm bone loss. Titanium and zirconia abutments-both of which are clinically durable-presented similar screw and fixture stress patterns. Therefore, clinicians should pay more attention to maintaining the peri-implant bone to achieve the long-term stability of the implant-supported prosthesis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.