ArticleInternational journal of environmental research and public health2022
Reliability and Usability Analysis of an Embedded System Capable of Evaluating Balance in Elderly Populations Based on a Modified Wii Balance Board.
Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Article
- Optimizing Fall Risk Diagnosis in Older Adults Using a Bayesian Classifier and Simulated Annealing.Bioengineering (Basel, Switzerland) · 2024Article
- Balance Problems in the Elderly with Diabetes Mellitus: A Literature Review.Journal of mid-life healthReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper analyzes the reliability and usability of a portable electronic instrument that measures balance and balance impairment in older adults. The center of pressure (CoP) metrics are measured with a modified Wii Balance Board (mWBB) platform. In the intra- and inter-rater testing, 16 and 43 volunteers (mean 75.66 and standard deviation (SD) of 7.86 years and 72.61 (SD 7.86) years, respectively) collaborated. Five volunteer raters (5.1 (SD 3.69) years of experience) answered the System Usability Scale (SUS). The most reliable CoP index in the intra-examiner tests was the 95% power frequency in the medial-lateral displacement of the CoP with closed-eyes. It had excellent reliability with an intraclass correlation coefficient ICC = 0.948 (C.I. 0.862-0.982) and a Pearson's correlation coefficient PCC = 0.966 (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.