Evidence map›Paper›PMID 36076356›Full record

ArticleOrthopaedic surgery2022

Morphological Changes of Medial Epicondyle-Olecranon Ligament and Ulnar Nerve in the Cubital Tunnel Syndrome: An Ultrasonic Study.

Xiao-Yuan Duan, Bin Xu, Jian-Xiong Ma, Ke-Tong Gong, Yu Yuan, Jin-Mei Gao, Xin-Long Ma

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xiao-Yuan DuanTianjin Hospital, Tianjin University, Tianjin, China.ORCID https://orcid.org/0000-0002-4392-7602
Bin XuTianjin Hospital, Tianjin University, Tianjin, China.
Jian-Xiong MaTianjin Hospital, Tianjin University, Tianjin, China.
Ke-Tong GongTianjin Hospital, Tianjin University, Tianjin, China.
Yu YuanTianjin Hospital, Tianjin University, Tianjin, China.ORCID https://orcid.org/0000-0002-4288-5172
Jin-Mei GaoTianjin Hospital, Tianjin University, Tianjin, China.
Xin-Long MaTianjin Hospital, Tianjin University, Tianjin, China.ORCID https://orcid.org/0000-0002-7064-6419
Tianjin University · CN

Funding

National Natural Science Foundation of China 81871777Tianjin Health Science and Technology Project RC20139
6 · The paper itself

Abstract

objectiveFew studies have performed detailed ultrasound measurements of medial epicondyle-olecranon (MEO) ligament that cause the entrapment of ulnar nerve. This study aims to comprehensively evaluate dynamic ultrasonographic characteristics of MEO ligament and ulnar nerve for clinical diagnosis and accurate treatment of cubital tunnel syndrome (CuTS).

methodsThirty CuTS patients (CuTS group) and sixteen healthy volunteers (control group) who underwent ultrasound scanning from October 2016 to October 2020 were retrospectively collected, with 30 elbows in each group. Primary outcomes were thickness at six points, length and width of MEO ligament. Secondary outcomes were thickness of ulnar nerve under MEO ligament at seven parts and the cross-sectional area (CSA) of ulnar nerve at proximal end of MEO ligament (P

resultsThickness of MEO ligament in CuTS group at epicondyle end, midpoint in transverse view, olecranon end, proximal end, midpoint in axial view, and distal end was 0.67 ± 0.31, 0.37 ± 0.18, 0.89 ± 0.35, 0.39 ± 0.21, 0.51 ± 0.38, 0.36 ± 0.25 at elbow extension, 0.68 ± 0.34, 0.38 ± 0.27, 0.77 ± 0.39, 0.32 ± 0.20, 0.48 ± 0.22, 0.32 ± 0.12 (mm) at elbow flexion, respectively. Compared with control group, they were significantly thickened except for proximal end at elbow flexion. MEO ligament thickness at epicondyle end and olecranon end was significantly larger than midpoint in two groups. No significant difference was found in length and width of MEO ligament among different comparisons. Ulnar nerve thickness at 5 mm proximal to MEO ligament (P

conclusionsMEO ligament in CuTS patients was thickened, which compressed ulnar nerve and caused its proximal end swelling. Ultrasonic image of MEO ligament thickness was a significant indicator for CuTS and can guide surgeons in selecting the appropriate treatment.

Indexed as

Cubital Tunnel SyndromeOlecranon ProcessHumansRetrospective StudiesUlnar NerveUltrasonicscubital tunnel syndromemedial epicondyle-olecranon ligamentulnar nerveultrasound

Identifiers

PMID36076356
PMCPMC9531097
OpenAlexW4295079392

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.