Evidence map›Paper›PMID 36076265›Full record

ArticleThe international journal of behavioral nutrition and physical activity2022

A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-adults study.

Jose Mora-Gonzalez, Zachary R Gould, Christopher C Moore, Elroy J Aguiar, Scott W Ducharme, John M Schuna, Tiago V Barreira, John Staudenmayer, Cayla R McAvoy, Mariya Boikova and 2 more

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in The international journal of behavioral nutrition and physical activity, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02650258 (Cadence and Intensity Across the Adult Lifespan), which is not on this map. Cited by 24 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 2 pooled it
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02650258 completednot on this map

Cadence and Intensity Across the Adult Lifespan

TypeobservationalSponsorUniversity of Massachusetts, AmherstRan2015 to 2019Enrolled260ConditionsAging, Walking, Motor Activity, Activities of Daily LivingArmstreadmill walking
3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 2 syntheses or guidelines pooled it, 41 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Sensors in Multiple Sclerosis.Current neurology and neuroscience reports · 2025
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Cadence (steps/min) and relative intensity in 61 to 85-year-olds: the CADENCE-Adults study.The international journal of behavioral nutrition and physical activity · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 7 institutions in 2 countries.

Jose Mora-GonzalezPROFITH "PROmoting FITness and Health Through Physical Activity" Research Group, Department of Physical Education and Sports, Faculty of Sport Sciences, Sport and Health University Research Institute (iMUDS), University of Granada, Granada, Spain.
Zachary R GouldDepartment of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA.
Christopher C MooreDepartment of Epidemiology, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
Elroy J AguiarDepartment of Kinesiology, The University of Alabama, Tuscaloosa, AL, USA.
Scott W DucharmeDepartment of Kinesiology, California State University, Long Beach, Long Beach, CA, USA.
John M SchunaSchool of Biological and Population Health Sciences, Oregon State University, Corvallis, OR, USA.
Tiago V BarreiraExercise Science Department, Syracuse University, Syracuse, NY, USA.
John StaudenmayerDepartment of Mathematics and Statistics, University of Massachusetts Amherst, Amherst, MA, USA.
Cayla R McAvoyCollege of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd, Charlotte, NC, 28223, USA.
Mariya BoikovaCollege of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd, Charlotte, NC, 28223, USA.
Taavy A MillerCollege of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd, Charlotte, NC, 28223, USA.
Catrine Tudor-LockeCollege of Health and Human Services, University of North Carolina at Charlotte, 9201 University City Blvd, Charlotte, NC, 28223, USA. Tudor-Locke@uncc.edu.ORCID 0000-0003-4342-5909
University of North Carolina at Charlotte · USUniversity of Massachusetts Amherst · USCalifornia State University, Long Beach · USOregon State University · USSyracuse University · USUniversity of Alabama · USUniversity of North Carolina at Chapel Hill · US

Funding

CADENCE-ADULTS: CADENCE AND INTENSITY ACROSS THE ADULT LIFESPANR01AG049024 · NIA · UNIVERSITY OF NORTH CAROLINA CHARLOTTE · PI TUDOR-LOCKE, CATRINE E. · 2015 to 2019
$2.7M
NIA NIH HHS R01 AG049024
6 · The paper itself

Abstract

backgroundStandardized validation indices (i.e., accuracy, bias, and precision) provide a comprehensive comparison of step counting wearable technologies. PURPOSE: To expand a previously published child/youth catalog of validity indices to include adults (21-40, 41-60 and 61-85 years of age) assessed across a range of treadmill speeds (slow [0.8-3.2 km/h], normal [4.0-6.4 km/h], fast [7.2-8.0 km/h]) and device wear locations (ankle, thigh, waist, and wrist).

methodsTwo hundred fifty-eight adults (52.5 ± 18.7 years, 49.6% female) participated in this laboratory-based study and performed a series of 5-min treadmill bouts while wearing multiple devices; 21 devices in total were evaluated over the course of this multi-year cross-sectional study (2015-2019). The criterion measure was directly observed steps. Computed validity indices included accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV).

resultsOver the range of normal speeds, 15 devices (Actical, waist-worn ActiGraph GT9X, activPAL, Apple Watch Series 1, Fitbit Ionic, Fitbit One, Fitbit Zip, Garmin vivoactive 3, Garmin vivofit 3, waist-worn GENEActiv, NL-1000, PiezoRx, Samsung Gear Fit2, Samsung Gear Fit2 Pro, and StepWatch) performed at < 5% MAPE. The wrist-worn ActiGraph GT9X displayed the worst accuracy across normal speeds (MAPE = 52%). On average, accuracy was compromised across slow walking speeds for all wearable technologies (MAPE = 40%) while all performed best across normal speeds (MAPE = 7%). When analyzing the data by wear locations, the ankle and thigh demonstrated the best accuracy (both MAPE = 1%), followed by the waist (3%) and the wrist (15%) across normal speeds. There were significant effects of speed, wear location, and age group on accuracy and bias (both p < 0.001) and precision (p ≤ 0.045).

conclusionsStandardized validation indices cataloged by speed, wear location, and age group across the adult lifespan facilitate selecting, evaluating, or comparing performance of step counting wearable technologies. Speed, wear location, and age displayed a significant effect on accuracy, bias, and precision. Overall, reduced performance was associated with very slow walking speeds (0.8 to 3.2 km/h). Ankle- and thigh-located devices logged the highest accuracy, while those located at the wrist reported the worst accuracy.

trial registrationClinicaltrials.gov NCT02650258. Registered 24 December 2015.

Indexed as

WalkingWearable Electronic DevicesAdultChildCross-Sectional StudiesExercise TestFemaleFitness TrackersHumansMaleReproducibility of ResultsAccelerometerAccuracyBiasMeasurementPedometerPhysical activity

Identifiers

PMID36076265
PMCPMC9461139
OpenAlexW4295078881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.